: Head-down bed rest (HDBR) reproduces the cardiovascular effects of microgravity. We tested the hypothesis that regular high-intensity physical exercise (JUMP) could prevent this cardiovascular deconditioning, which could be detected using seismocardiography (SCG) and ballistocardiography (BCG). 23 healthy males were exposed to 60-day HDBR: 12 in a physical exercise group (JUMP), the others in a control group (CTRL). SCG and BCG were measured during supine controlled breathing protocols. From the linear and rotational SCG/BCG signals, the integral of kinetic energy ([Formula: see text]) was computed on each dimension over the cardiac cycle. At the end of HDBR, BCG rotational [Formula: see text] and SCG transversal [Formula: see text] decreased similarly for all participants (- 40% and - 44%, respectively, p < 0.05), and so did orthostatic tolerance (- 58%, p < 0.01). Resting heart rate decreased in JUMP (- 10%, p < 0.01), but not in CTRL. BCG linear [Formula: see text] decreased in CTRL (- 50%, p < 0.05), but not in JUMP. The changes in the systolic component of BCG linear iK were correlated to those in stroke volume and VO2 max (R = 0.44 and 0.47, respectively, p < 0.05). JUMP was less affected by cardiovascular deconditioning, which could be detected by BCG in agreement with standard markers of the cardiovascular condition. This shows the potential of BCG to easily monitor cardiac deconditioning.

Cardiovascular adaptation to simulated microgravity and countermeasure efficacy assessed by ballistocardiography and seismocardiography

Caiani, Enrico G;
2020-01-01

Abstract

: Head-down bed rest (HDBR) reproduces the cardiovascular effects of microgravity. We tested the hypothesis that regular high-intensity physical exercise (JUMP) could prevent this cardiovascular deconditioning, which could be detected using seismocardiography (SCG) and ballistocardiography (BCG). 23 healthy males were exposed to 60-day HDBR: 12 in a physical exercise group (JUMP), the others in a control group (CTRL). SCG and BCG were measured during supine controlled breathing protocols. From the linear and rotational SCG/BCG signals, the integral of kinetic energy ([Formula: see text]) was computed on each dimension over the cardiac cycle. At the end of HDBR, BCG rotational [Formula: see text] and SCG transversal [Formula: see text] decreased similarly for all participants (- 40% and - 44%, respectively, p < 0.05), and so did orthostatic tolerance (- 58%, p < 0.01). Resting heart rate decreased in JUMP (- 10%, p < 0.01), but not in CTRL. BCG linear [Formula: see text] decreased in CTRL (- 50%, p < 0.05), but not in JUMP. The changes in the systolic component of BCG linear iK were correlated to those in stroke volume and VO2 max (R = 0.44 and 0.47, respectively, p < 0.05). JUMP was less affected by cardiovascular deconditioning, which could be detected by BCG in agreement with standard markers of the cardiovascular condition. This shows the potential of BCG to easily monitor cardiac deconditioning.
2020
File in questo prodotto:
File Dimensione Formato  
Rabineau_et_al-2020-Scientific_Reports.pdf

accesso aperto

: Publisher’s version
Dimensione 1.5 MB
Formato Adobe PDF
1.5 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1226809
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 12
social impact