The article describes detailed measurements of indoor environmental parameters in a multiapartment housing block located in Milan, Italy, which has recently undergone a deep energy retrofit and is used as a thermal battery during the winter season. Two datasets are provided: one refers to a series of experimental tests conducted by the authors in an unoccupied flat, in which the thermal capacity of the building mass is exploited to act as an energy storage. The dataset reports, with a time step of 10 min, measurements of air temperature, globe temperature and surface temperatures in the analyzed room and data characterizing the adjacent spaces and the outdoor conditions. The second set of data refers to the air temperature monitoring carried out continuously in all the apartments of the apartment block, and hence also during two unplanned heating power outages. The analyzed data show the role of deep renovations in extending the time over which a building can remain in the thermal comfort range after an energy interruption and thus highlight the potential role of retrofitted buildings in delivering energy flexibility services to related stakeholders, such as the occupants, the building manager, the grid operator, and others. Furthermore, the dataset can be used to calibrate an energy simulation model to investigate different demand-side flexibility strategies and evaluate thermal safety under extreme weather events.

Measured Indoor Environmental Data in a Retrofitted Multiapartment Building to Assess Energy Flexibility and Thermal Safety during Winter Power Outages

Erba, Silvia;Barbieri, Alessandra
2022-01-01

Abstract

The article describes detailed measurements of indoor environmental parameters in a multiapartment housing block located in Milan, Italy, which has recently undergone a deep energy retrofit and is used as a thermal battery during the winter season. Two datasets are provided: one refers to a series of experimental tests conducted by the authors in an unoccupied flat, in which the thermal capacity of the building mass is exploited to act as an energy storage. The dataset reports, with a time step of 10 min, measurements of air temperature, globe temperature and surface temperatures in the analyzed room and data characterizing the adjacent spaces and the outdoor conditions. The second set of data refers to the air temperature monitoring carried out continuously in all the apartments of the apartment block, and hence also during two unplanned heating power outages. The analyzed data show the role of deep renovations in extending the time over which a building can remain in the thermal comfort range after an energy interruption and thus highlight the potential role of retrofitted buildings in delivering energy flexibility services to related stakeholders, such as the occupants, the building manager, the grid operator, and others. Furthermore, the dataset can be used to calibrate an energy simulation model to investigate different demand-side flexibility strategies and evaluate thermal safety under extreme weather events.
2022
globe temperature
surface temperature
operative temperature
demand-side flexibility
heating power outage
deep energy retrofit
thermal mass
thermal safety
thermal comfort
air temperature
File in questo prodotto:
File Dimensione Formato  
Erba_Measured Indoor Environmental Data in a Retrofitted Multiapartment Building to Assess Energy Flexibility and Thermal Safety during Winter Power Outages.pdf

accesso aperto

Descrizione: Published version
: Publisher’s version
Dimensione 6.28 MB
Formato Adobe PDF
6.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1226524
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact