Computational models are increasingly used to assess spine biomechanics and support surgical planning. However, varying levels of model verification and validation, along with characterization of uncertainty effects limit the level of confidence in their predictive potential. The objective was to assess the credibility of an adult spine deformity instrumentation model for proximal junction failure (PJF) analysis using the ASME V&V40:2018 framework. To assess model applicability, the surgery, erected posture, and flexion movement of actual clinical cases were simulated. The loads corresponding to PJF indicators for a group of asymptomatic patients and a group of PJF patients were compared. Model consistency was demonstrated by finding PJF indicators significantly higher for the simulated PJF vs. asymptomatic patients. A detailed sensitivity analysis and uncertainty quantification were performed to further establish the model credibility.

Credibility assessment of patient-specific biomechanical models to investigate proximal junctional failure in clinical cases with adult spine deformity using ASME V&V40 standard

La Barbera L.;
2021-01-01

Abstract

Computational models are increasingly used to assess spine biomechanics and support surgical planning. However, varying levels of model verification and validation, along with characterization of uncertainty effects limit the level of confidence in their predictive potential. The objective was to assess the credibility of an adult spine deformity instrumentation model for proximal junction failure (PJF) analysis using the ASME V&V40:2018 framework. To assess model applicability, the surgery, erected posture, and flexion movement of actual clinical cases were simulated. The loads corresponding to PJF indicators for a group of asymptomatic patients and a group of PJF patients were compared. Model consistency was demonstrated by finding PJF indicators significantly higher for the simulated PJF vs. asymptomatic patients. A detailed sensitivity analysis and uncertainty quantification were performed to further establish the model credibility.
2021
biomechanics
Proximal junctional failure
scoliosis
spine
verification and validation
modelling
File in questo prodotto:
File Dimensione Formato  
2022 Lopez-Poncelas_V&V40 PJK.pdf

Accesso riservato

: Publisher’s version
Dimensione 2.65 MB
Formato Adobe PDF
2.65 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1211120
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact