The current paper aims at analysing the effect of ground motion vertical component in the case of near-field excitations on the structural response of historical masonry buildings. In this perspective, the Banloc Castle in Romania has been considered as a reference case study. This historical masonry structure was damaged by the Banat-Voiteg earthquake that occurred in December 1991 in the homonymous city. To this purpose, a FEM model of the building, set up using the DIANA FEA analysis software, has been studied in the non-linear dynamic field considering a real ground motion record based on specific source-to-site distance, moment magnitude and focal depth. The effects of the impulsive earthquake have been evaluated considering the main engineering demand parameters, such as displacements and forces, focusing on two different scenarios, namely horizontal and horizontal + vertical ground motions. The obtained results have shown that the vertical ground motion sensibly modifies the structural capacity of the building since it produces a relevant modification of the in-plane walls behaviour and the stress conditions. Important considerations about the behaviour (or seismic response modification) factor, ductility and stress in terms of axial and shear forces have been provided. Moreover, numerical damage patterns have been compared to the real cracks detected. Finally, a set of fragility curves has been derived taking into consideration the near-field effects.

The effect of ground motion vertical component on the seismic response of historical masonry buildings: The case study of the Banloc Castle in Romania

Formisano A.;Milani G.
2021-01-01

Abstract

The current paper aims at analysing the effect of ground motion vertical component in the case of near-field excitations on the structural response of historical masonry buildings. In this perspective, the Banloc Castle in Romania has been considered as a reference case study. This historical masonry structure was damaged by the Banat-Voiteg earthquake that occurred in December 1991 in the homonymous city. To this purpose, a FEM model of the building, set up using the DIANA FEA analysis software, has been studied in the non-linear dynamic field considering a real ground motion record based on specific source-to-site distance, moment magnitude and focal depth. The effects of the impulsive earthquake have been evaluated considering the main engineering demand parameters, such as displacements and forces, focusing on two different scenarios, namely horizontal and horizontal + vertical ground motions. The obtained results have shown that the vertical ground motion sensibly modifies the structural capacity of the building since it produces a relevant modification of the in-plane walls behaviour and the stress conditions. Important considerations about the behaviour (or seismic response modification) factor, ductility and stress in terms of axial and shear forces have been provided. Moreover, numerical damage patterns have been compared to the real cracks detected. Finally, a set of fragility curves has been derived taking into consideration the near-field effects.
2021
Damage Assessment
Fragility curves
Historical Masonry Building
Near-field effects
Seismic Vulnerability Assessment
Vertical Ground Motion
File in questo prodotto:
File Dimensione Formato  
2021_ES9.pdf

Accesso riservato

Descrizione: 2021_ES_Mosoarca_et_al
: Publisher’s version
Dimensione 23.35 MB
Formato Adobe PDF
23.35 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1193779
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 27
social impact