In recent decades, steel-reinforced concrete (SRC) members under eccentrical tension have been adopted more frequently in modern buildings due to the constraints of more complex structural design/detailing that accompanying contemporary architectural creations. Crack resistance of this type of structures has become a critical design consideration but received insufficient research attention in the past. In this context, the anti-cracking performance of prestressed SRC columns reinforced with CFRP tendons under eccentric tensile loads is investigated experimentally and analytically with the following first-hand experimental validations: 1) prestressed CFRP tendons can well strengthen SRC columns under eccentric tensile load and restrain the crack propagation; 2) an increase in the load eccentricity progressively weakened the influence of prestressing tension level on the cracking load; 3) specimens with the higher prestressed tension level, larger longitudinal reinforcement diameter, and flange thickness exhibited greater crack resistance capacity. Furthermore, the plane-section assumption was also validated in this study. A test data-enhanced analytical method was proposed for determining the cracking load of PSRC columns.
Study on crack width and crack resistance of eccentrically tensioned steel-reinforced concrete members prestressed by CFRP tendons
Taliercio A.;
2022-01-01
Abstract
In recent decades, steel-reinforced concrete (SRC) members under eccentrical tension have been adopted more frequently in modern buildings due to the constraints of more complex structural design/detailing that accompanying contemporary architectural creations. Crack resistance of this type of structures has become a critical design consideration but received insufficient research attention in the past. In this context, the anti-cracking performance of prestressed SRC columns reinforced with CFRP tendons under eccentric tensile loads is investigated experimentally and analytically with the following first-hand experimental validations: 1) prestressed CFRP tendons can well strengthen SRC columns under eccentric tensile load and restrain the crack propagation; 2) an increase in the load eccentricity progressively weakened the influence of prestressing tension level on the cracking load; 3) specimens with the higher prestressed tension level, larger longitudinal reinforcement diameter, and flange thickness exhibited greater crack resistance capacity. Furthermore, the plane-section assumption was also validated in this study. A test data-enhanced analytical method was proposed for determining the cracking load of PSRC columns.File | Dimensione | Formato | |
---|---|---|---|
166_preprint.pdf
Open Access dal 02/02/2024
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
1.67 MB
Formato
Adobe PDF
|
1.67 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.