In this paper, the energy performance of a university campus in a tropical climate is assessed, and four mixed classroom buildings are compared using benchmarking methods based on simple normalization: the classic Energy Use Intensity (EUI), end-used based EUI, and people- based EUI. To estimate the energy consumption of the case studies, building energy simulations were carried out in EnergyPlus using custom inputs. The analysis found that buildings with more classroom spaces presented higher energy consumption for cooling and lighting than others. In comparison, buildings with a greater percentage of laboratories and offices exhibited higher energy consumption for plug loads. Nevertheless, differences were identified when using the people-based EUI since buildings with larger floor areas showed the highest values, highlighting the impact of occupant behavior on energy consumption. Given the fact that little is known about a benchmark range for university campuses and academic buildings in hot and humid climates, this paper also provides a comparison against the EUIs reported in the literature for both cases. In this sense, the identified range for campuses was 49–367 kWh/m2/year, while for academic buildings, the range was 47–628 kWh/m2/year. Overall, the findings of this study could contribute to identifying better-targeted energy efficiency strategies for the studied buildings in the future by assessing their performance under different indicators and drawing a benchmark to compare similar buildings in hot and humid climates.

Energy Performance and Benchmarking for University Classrooms in Hot and Humid Climates

Litardo, Jaqueline;
2021-01-01

Abstract

In this paper, the energy performance of a university campus in a tropical climate is assessed, and four mixed classroom buildings are compared using benchmarking methods based on simple normalization: the classic Energy Use Intensity (EUI), end-used based EUI, and people- based EUI. To estimate the energy consumption of the case studies, building energy simulations were carried out in EnergyPlus using custom inputs. The analysis found that buildings with more classroom spaces presented higher energy consumption for cooling and lighting than others. In comparison, buildings with a greater percentage of laboratories and offices exhibited higher energy consumption for plug loads. Nevertheless, differences were identified when using the people-based EUI since buildings with larger floor areas showed the highest values, highlighting the impact of occupant behavior on energy consumption. Given the fact that little is known about a benchmark range for university campuses and academic buildings in hot and humid climates, this paper also provides a comparison against the EUIs reported in the literature for both cases. In this sense, the identified range for campuses was 49–367 kWh/m2/year, while for academic buildings, the range was 47–628 kWh/m2/year. Overall, the findings of this study could contribute to identifying better-targeted energy efficiency strategies for the studied buildings in the future by assessing their performance under different indicators and drawing a benchmark to compare similar buildings in hot and humid climates.
2021
Energy Use Intensity; higher education buildings; energy consumption; benchmarking; hot and humid climates; EnergyPlus
File in questo prodotto:
File Dimensione Formato  
energies-14-07013.pdf

accesso aperto

: Publisher’s version
Dimensione 4.45 MB
Formato Adobe PDF
4.45 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1188829
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 8
social impact