This paper describes an inexpensive, non-invasive and highly adaptable surface reconstruction device for opaque liquids. The instrument was developed to study the lateral sloshing of ferrofluids in microgravity as part of the UNOOSA DropTES 2019 StELIUM project. Its design is driven by the geometrical and mechanical constraints imposed by ZARM's drop tower, where the experiment was launched in November 2019. The launch catapult and deceleration systems impose strong axial g-loads to a system that is confined in the reduced capsule environment. Redundant procedures are implemented to measure the first two lateral sloshing frequencies and damping ratios of the magnetic liquid, as well as its equilibrium surface in microgravity. Ideal vertical resolutions between 0.25 and 0.4 mm/px can be achieved with the configuration here proposed. The final performance depends, among other factors, on the correct application of the robust calibration procedure that is documented in this work.

Free surface reconstruction of opaque liquids in microgravity, Part 1: Design and on-ground testing

Maggi F.
2021-01-01

Abstract

This paper describes an inexpensive, non-invasive and highly adaptable surface reconstruction device for opaque liquids. The instrument was developed to study the lateral sloshing of ferrofluids in microgravity as part of the UNOOSA DropTES 2019 StELIUM project. Its design is driven by the geometrical and mechanical constraints imposed by ZARM's drop tower, where the experiment was launched in November 2019. The launch catapult and deceleration systems impose strong axial g-loads to a system that is confined in the reduced capsule environment. Redundant procedures are implemented to measure the first two lateral sloshing frequencies and damping ratios of the magnetic liquid, as well as its equilibrium surface in microgravity. Ideal vertical resolutions between 0.25 and 0.4 mm/px can be achieved with the configuration here proposed. The final performance depends, among other factors, on the correct application of the robust calibration procedure that is documented in this work.
2021
3D reconstruction
Ferrofluids
Liquid interface
Magnetic liquid sloshing
Microgravity
File in questo prodotto:
File Dimensione Formato  
ROMEA01-21.pdf

Accesso riservato

Descrizione: Paper
: Publisher’s version
Dimensione 2.13 MB
Formato Adobe PDF
2.13 MB Adobe PDF   Visualizza/Apri
ROMEA_OA_01-21.pdf

Open Access dal 30/08/2023

Descrizione: Paper Open Access
: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 3.19 MB
Formato Adobe PDF
3.19 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1187126
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact