Many typical historical masonry churches, with one nave and wooden roofs, have shown high seismic vulnerability in the recent seismic events, especially under transverse earthquakes. In fact, the nave transverse response of this kind of constructions is influenced both by the materials features and the geometrical characteristics. In order to improve the seismic response, the box behavior strategy basing on dissipative roof-diaphragm, can be pursued by adopting cross laminated timber panels (CLT). In this paper, for five historical masonry churches, the effectiveness of different CLT panels solutions is investigated by performing comparative non-linear dynamic analyses adopting equivalent finite element models. The CLT solutions differ themselves for the panels thickness (6mm and 10mm) and the number of the connections (8,16 and 32 crews in one linear meter). The results are shown in terms of dimensionless transverse displacement (drift) and shear occurred at the base of the façade. Therefore, the influence of the most important geometrical features (as slenderness of the perimeter walls, the width and the length of the churches) in the seismic response is pointed out for each church equipped by different CLT roof-diaphragm solutions.

Evaluation of the seismic behavior of historical churches reinforced by cross-lam roof-structure

Nicola Longarini;Pietro Crespi;Marco Zucca
2021-01-01

Abstract

Many typical historical masonry churches, with one nave and wooden roofs, have shown high seismic vulnerability in the recent seismic events, especially under transverse earthquakes. In fact, the nave transverse response of this kind of constructions is influenced both by the materials features and the geometrical characteristics. In order to improve the seismic response, the box behavior strategy basing on dissipative roof-diaphragm, can be pursued by adopting cross laminated timber panels (CLT). In this paper, for five historical masonry churches, the effectiveness of different CLT panels solutions is investigated by performing comparative non-linear dynamic analyses adopting equivalent finite element models. The CLT solutions differ themselves for the panels thickness (6mm and 10mm) and the number of the connections (8,16 and 32 crews in one linear meter). The results are shown in terms of dimensionless transverse displacement (drift) and shear occurred at the base of the façade. Therefore, the influence of the most important geometrical features (as slenderness of the perimeter walls, the width and the length of the churches) in the seismic response is pointed out for each church equipped by different CLT roof-diaphragm solutions.
2021
COMPDYN 2021 - 8th ECCOMAS Thematic Conference on Computational Methods in Structural Dynamics and Earthquake Engineering
Historical Churches, Seismic Vulnerability, Roof-Diaphragm, Time-History analysis
File in questo prodotto:
File Dimensione Formato  
18719.pdf

Accesso riservato

Descrizione: Articolo principale
: Publisher’s version
Dimensione 1.95 MB
Formato Adobe PDF
1.95 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1181802
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact