Full-scale testing of a two-storey flat slab structure is reported, undertaken in the SlabSTRESS research project; the construction and testing were planned and carried out at the ELSA laboratory of the European Commission’s Joint Research Centre. The dimensions are three bays by two, spans 4.5 and 5 m, slab thickness 0.2 m, interstorey height 3.2 m. Two different longitudinal reinforcement details were considered; welded studs shear reinforcement was provided only in the second floor slab. The testing program included seismic tests for service and ultimate actions, using the pseudodynamic technique with virtual walls. To this aim a building structure was designed with primary walls and the flat slab frame as secondary element. Cyclic loading tests followed up to ultimate drift capacity of the structure. The sequence of tests included strengthening of a set of damaged connections using bolted bars in holes drilled through the slab, followed by cyclic testing to failure. The instrumentation was provided for the global response and the connections with local rotations in the columns and slab; cracking around the columns was measured with through-crack sensors; a measurement system for internal forces and moments was included within the columns. The results show the response with deformations and damage for the different loading conditions up to failure. The results obtained on a full-scale structure extend and confirm the knowledge in the literature, mainly based on isolated connections and/or small-scale samples.

Testing of a full-scale flat slab building for gravity and lateral loads

Dario Coronelli;Luca Martinelli;
2021-01-01

Abstract

Full-scale testing of a two-storey flat slab structure is reported, undertaken in the SlabSTRESS research project; the construction and testing were planned and carried out at the ELSA laboratory of the European Commission’s Joint Research Centre. The dimensions are three bays by two, spans 4.5 and 5 m, slab thickness 0.2 m, interstorey height 3.2 m. Two different longitudinal reinforcement details were considered; welded studs shear reinforcement was provided only in the second floor slab. The testing program included seismic tests for service and ultimate actions, using the pseudodynamic technique with virtual walls. To this aim a building structure was designed with primary walls and the flat slab frame as secondary element. Cyclic loading tests followed up to ultimate drift capacity of the structure. The sequence of tests included strengthening of a set of damaged connections using bolted bars in holes drilled through the slab, followed by cyclic testing to failure. The instrumentation was provided for the global response and the connections with local rotations in the columns and slab; cracking around the columns was measured with through-crack sensors; a measurement system for internal forces and moments was included within the columns. The results show the response with deformations and damage for the different loading conditions up to failure. The results obtained on a full-scale structure extend and confirm the knowledge in the literature, mainly based on isolated connections and/or small-scale samples.
2021
File in questo prodotto:
File Dimensione Formato  
pagination_JEST_112551.pdf

Accesso riservato

: Publisher’s version
Dimensione 9.56 MB
Formato Adobe PDF
9.56 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1178755
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 9
social impact