The current work describes a method for dealing with an anomalous background observed in parallel to the signal of interest (X-rays or gammas) on spectroscopic Silicon Drift Detectors (SDD) arrays exposed to large fluxes of ionizing radiation. The increment could not be explained by the Monte Carlo simulation reproducing well the single SDD cell response and containing realistic multi-cell array structure, neither by measurements on single devices. After rejecting the cross-talk hypothesis, an asymmetry in the drift time distribution brought attention to the primary signal structure, eventually reaching the conclusion that the effect comes from the minimum ionizing particles (MIP) induced charge, shared between the SDD cells. Successively, an analysis of three signal parameters (amplitude, drift time and rise time) brought up a solution and two practical implementations, at different cost and performance levels.

Reducing the MIPs charge-sharing background in X-ray spectroscopic SDD arrays

Amirkhani A.;Fiorini C.;
2021-01-01

Abstract

The current work describes a method for dealing with an anomalous background observed in parallel to the signal of interest (X-rays or gammas) on spectroscopic Silicon Drift Detectors (SDD) arrays exposed to large fluxes of ionizing radiation. The increment could not be explained by the Monte Carlo simulation reproducing well the single SDD cell response and containing realistic multi-cell array structure, neither by measurements on single devices. After rejecting the cross-talk hypothesis, an asymmetry in the drift time distribution brought attention to the primary signal structure, eventually reaching the conclusion that the effect comes from the minimum ionizing particles (MIP) induced charge, shared between the SDD cells. Successively, an analysis of three signal parameters (amplitude, drift time and rise time) brought up a solution and two practical implementations, at different cost and performance levels.
2021
Anodes
Calibration
Charge sharing
Detectors
Electron tubes
Fluorescence
Iron
Spectroscopy
Timing
X-ray detectors
File in questo prodotto:
File Dimensione Formato  
Reducing the MIPs Charge-Sharing Background.pdf

Accesso riservato

: Publisher’s version
Dimensione 7.92 MB
Formato Adobe PDF
7.92 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1171118
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact