Electric faults in photovoltaic (PV) systems cause negative economic and safety impacts, reducing their performance and causing unwanted electric connections that can be dangerous for the user. Line to line, ground and open circuit faults, are three of the main faults that happen in a photovoltaic array system. This work proposes a characterization of the equivalent circuits and the voltage-power (VP) curves at the output of multiple PV arrays under different topological configurations and fault conditions to evaluate the effects of these three main faults on the performance of a photovoltaic array system, taking into account the temperature and solar radiation influence. This work presents a validation of the characterization by measuring the output VP curves of a low-power photovoltaic array system under real outdoors conditions. This method can be useful in future works to develop low cost systems capable of detecting and classifying electric faults in photovoltaic array systems.

Characterization of electric faults in photovoltaic array systems

Ruiz, Fredy;
2019-01-01

Abstract

Electric faults in photovoltaic (PV) systems cause negative economic and safety impacts, reducing their performance and causing unwanted electric connections that can be dangerous for the user. Line to line, ground and open circuit faults, are three of the main faults that happen in a photovoltaic array system. This work proposes a characterization of the equivalent circuits and the voltage-power (VP) curves at the output of multiple PV arrays under different topological configurations and fault conditions to evaluate the effects of these three main faults on the performance of a photovoltaic array system, taking into account the temperature and solar radiation influence. This work presents a validation of the characterization by measuring the output VP curves of a low-power photovoltaic array system under real outdoors conditions. This method can be useful in future works to develop low cost systems capable of detecting and classifying electric faults in photovoltaic array systems.
2019
File in questo prodotto:
File Dimensione Formato  
79085-Texto del artículo-447955-1-10-20191205.pdf

Accesso riservato

Descrizione: Articolo
: Publisher’s version
Dimensione 1.46 MB
Formato Adobe PDF
1.46 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1162775
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact