In this paper we propose multispectrum rotational states distribution thermometry as an optical method for primary thermometry. It relies on a global fitting of multiple absorption lines of the same band at different pressures. The approach allows leveraging both the temperature-dependent Doppler width and the temperature-dependent distribution of line intensities across the ro-vibrational band. We provide a proof-of-principle demonstration of the approach on the 3ν 1 + ν 3 band of CO2, for which several accurate line-strength models of both theoretical and experimental origin are available for the global fitting. Our experimental conditions do not allow to test the methodology beyond a combined uncertainty of 530 ppm, but the comparative analysis between different line-strength models shows promise to reduce the error budget to few tens of ppm. As compared to Doppler-broadening thermometry, the approach is advantageous to mitigate systematic errors induced by a wrong modelling of absorption line-shapes and to reduce, for a given experimental dataset, the statistical uncertainty by a factor of 2. When applied in a reverse way, i.e. using a gas of known temperature, the approach becomes a stringent testbed for the accuracy of the adopted line-strength model.

Multispectrum rotational states distribution thermometry: Application to the 3ν 1+ ν 3band of carbon dioxide

Gotti R.;Lamperti M.;Gatti D.;Laporta P.;Marangoni M.
2020-01-01

Abstract

In this paper we propose multispectrum rotational states distribution thermometry as an optical method for primary thermometry. It relies on a global fitting of multiple absorption lines of the same band at different pressures. The approach allows leveraging both the temperature-dependent Doppler width and the temperature-dependent distribution of line intensities across the ro-vibrational band. We provide a proof-of-principle demonstration of the approach on the 3ν 1 + ν 3 band of CO2, for which several accurate line-strength models of both theoretical and experimental origin are available for the global fitting. Our experimental conditions do not allow to test the methodology beyond a combined uncertainty of 530 ppm, but the comparative analysis between different line-strength models shows promise to reduce the error budget to few tens of ppm. As compared to Doppler-broadening thermometry, the approach is advantageous to mitigate systematic errors induced by a wrong modelling of absorption line-shapes and to reduce, for a given experimental dataset, the statistical uncertainty by a factor of 2. When applied in a reverse way, i.e. using a gas of known temperature, the approach becomes a stringent testbed for the accuracy of the adopted line-strength model.
2020
frequency combs
molecular spectroscopy
primary thermometry
File in questo prodotto:
File Dimensione Formato  
11311-1157607_Marangoni.pdf

accesso aperto

: Publisher’s version
Dimensione 1.98 MB
Formato Adobe PDF
1.98 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1157607
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 4
social impact