We characterized the biologic background of prothrombotic platelet function in the setting of durable left ventricular assist devices (LVADs) evaluating the role of different antithrombotic regimens. Platelet-mediated thrombin generation was quantified using the Platelet Activity State (PAS) Assay and the Thrombin Generation Test (TGT) in 78 patients implanted with the HeartMate II (n = 10, 13%), the HeartMate 3 (HM3) (n = 30, 38%), or the HVAD (n = 38, 49%) and managed with oral anticoagulation plus aspirin (n = 46, 59%) or anticoagulation alone (n = 32, 41%). Coagulation parameters (platelet count, International Normalized Ratio (INR), activated Partial Thromboplastin Time, Fibrinogen and D-Dimer levels) and hemolysis (lactate dehydrogenase levels [LDH]) were also recorded to comprehensively characterize the hemostatic profile in the two groups. In patients without aspirin, the PAS assay revealed low-intensity increase in platelet prothrombinase activity (1.11-fold, p = 0.03). Similarly the TGT revealed moderate higher platelet reactivity when compared with patients receiving aspirin, consistent with reduction in lag time (0.87-fold, p < 0.001), increase in peak of thrombin generation (1.5-fold, p = 0.002) and thrombin generation rate (2-fold, p = 0.02), but comparable endogenous thrombin potential (p = 0.50). Coagulation parameters and LDH were comparable in the two groups (p > 0.05). Moreover, no differences were noted in platelet prothrombinase activity of patients implanted with the HM3 or HVAD. Our results suggest that, in the setting of durable LVADs, aspirin minimally modulates the biochemical pathway of platelet-mediated thrombin generation. Accordingly, re-evaluation of current antithrombotic management criteria in patients stratified according to bleeding/thromboembolic risk might be safe and beneficial to prevent adverse events.

Influence of different antithrombotic regimens on platelet-mediated thrombin generation in patients with left ventricular assist devices

Consolo F.;Redaelli A.;
2020-01-01

Abstract

We characterized the biologic background of prothrombotic platelet function in the setting of durable left ventricular assist devices (LVADs) evaluating the role of different antithrombotic regimens. Platelet-mediated thrombin generation was quantified using the Platelet Activity State (PAS) Assay and the Thrombin Generation Test (TGT) in 78 patients implanted with the HeartMate II (n = 10, 13%), the HeartMate 3 (HM3) (n = 30, 38%), or the HVAD (n = 38, 49%) and managed with oral anticoagulation plus aspirin (n = 46, 59%) or anticoagulation alone (n = 32, 41%). Coagulation parameters (platelet count, International Normalized Ratio (INR), activated Partial Thromboplastin Time, Fibrinogen and D-Dimer levels) and hemolysis (lactate dehydrogenase levels [LDH]) were also recorded to comprehensively characterize the hemostatic profile in the two groups. In patients without aspirin, the PAS assay revealed low-intensity increase in platelet prothrombinase activity (1.11-fold, p = 0.03). Similarly the TGT revealed moderate higher platelet reactivity when compared with patients receiving aspirin, consistent with reduction in lag time (0.87-fold, p < 0.001), increase in peak of thrombin generation (1.5-fold, p = 0.002) and thrombin generation rate (2-fold, p = 0.02), but comparable endogenous thrombin potential (p = 0.50). Coagulation parameters and LDH were comparable in the two groups (p > 0.05). Moreover, no differences were noted in platelet prothrombinase activity of patients implanted with the HM3 or HVAD. Our results suggest that, in the setting of durable LVADs, aspirin minimally modulates the biochemical pathway of platelet-mediated thrombin generation. Accordingly, re-evaluation of current antithrombotic management criteria in patients stratified according to bleeding/thromboembolic risk might be safe and beneficial to prevent adverse events.
2020
Antiplatelet therapy
Aspirin
Left ventricular assist device
Mechanical circulatory support
Thrombin generation
Blood Coagulation
Blood Platelets
Fibrin Fibrinogen Degradation Products
Fibrinolytic Agents
Heart-Assist Devices
File in questo prodotto:
File Dimensione Formato  
2020_Consolo_ASAIOJ.pdf

Open Access dal 02/05/2021

: Publisher’s version
Dimensione 240.05 kB
Formato Adobe PDF
240.05 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1154771
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 15
social impact