Magnesium is an essential element for the ocular functions and used for the realization of medical de- vices due to its low corrosion resistance, bioresorbable nature and biocompatibility. Wet age-related mac- ular degeneration is one of the main causes of blindness with patients treated by intravitreal injections of inhibitor drugs. According to the need to reduce the number of injections, the development of new drug delivery devices able to extend the therapeutical outcomes is mandatory and magnesium can be considered as a promising candidate. The aim of the work concerns the evaluation of the ocular fluid dy- namic role on a magnesium-based device placed in the vitreous chamber. Particularly, the fluid-induced shear stress field on the surfaces in contact with the liquefied vitreous was studied. Both computational fluid dynamic and fluid-structure interaction approaches were proposed and then compared. Saccadic motion was implemented to recreate the vitreous fluid dynamics. High changes in terms of fluid-induced shear stress field varying the CFD and FSI numerical approaches and kinematic parameters of the saccadic function can be noticed. The comparison between CFD and FSI approaches showed minor significant dif- ferences and both implementations suggested the possibility to obtain a uniform and controlled corrosion of the device.

Evaluation of the ocular fluid dynamic effects on intraocular magnesium-based device: A comparison between CFD and FSI approaches

Ferroni, Marco;De Gaetano, Francesco;Boschetti, Federica
2020-01-01

Abstract

Magnesium is an essential element for the ocular functions and used for the realization of medical de- vices due to its low corrosion resistance, bioresorbable nature and biocompatibility. Wet age-related mac- ular degeneration is one of the main causes of blindness with patients treated by intravitreal injections of inhibitor drugs. According to the need to reduce the number of injections, the development of new drug delivery devices able to extend the therapeutical outcomes is mandatory and magnesium can be considered as a promising candidate. The aim of the work concerns the evaluation of the ocular fluid dy- namic role on a magnesium-based device placed in the vitreous chamber. Particularly, the fluid-induced shear stress field on the surfaces in contact with the liquefied vitreous was studied. Both computational fluid dynamic and fluid-structure interaction approaches were proposed and then compared. Saccadic motion was implemented to recreate the vitreous fluid dynamics. High changes in terms of fluid-induced shear stress field varying the CFD and FSI numerical approaches and kinematic parameters of the saccadic function can be noticed. The comparison between CFD and FSI approaches showed minor significant dif- ferences and both implementations suggested the possibility to obtain a uniform and controlled corrosion of the device.
2020
File in questo prodotto:
File Dimensione Formato  
2020 Ocular FSI-CFD.pdf

Accesso riservato

Descrizione: articolo
: Publisher’s version
Dimensione 2.43 MB
Formato Adobe PDF
2.43 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1152664
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact