DC stray currents may induce corrosion on buried carbon steel pipelines transporting methane even if in cathodic protection. According to international standard, anodic interference is unacceptable if the IR-free potential is more positive than the protection potential (−0.85 V CSE). But, duration and magnitude of the anodic peak is not defined. This paper describes results of laboratory tests performed in soil-simulating environment on cathodically protected carbon steel specimens suffering DC interference at varying peak current density, anodic potential and duration. Measured corrosion rate is always lower than the theoretical value predicted by Faraday Law. Consequently, it is possible to conclude that cathodic protection has a positive effect towards DC interference. A parameter Time Out of Protection has been defined as the period of time during interference where the potential is more positive than −0.85 V CSE; this factor has been correlated to the measured potential during DC interference.

Cathodic protection and DC non-stationary anodic interference

Attarchi M.;Brenna A.;Ormellese M.
2020-01-01

Abstract

DC stray currents may induce corrosion on buried carbon steel pipelines transporting methane even if in cathodic protection. According to international standard, anodic interference is unacceptable if the IR-free potential is more positive than the protection potential (−0.85 V CSE). But, duration and magnitude of the anodic peak is not defined. This paper describes results of laboratory tests performed in soil-simulating environment on cathodically protected carbon steel specimens suffering DC interference at varying peak current density, anodic potential and duration. Measured corrosion rate is always lower than the theoretical value predicted by Faraday Law. Consequently, it is possible to conclude that cathodic protection has a positive effect towards DC interference. A parameter Time Out of Protection has been defined as the period of time during interference where the potential is more positive than −0.85 V CSE; this factor has been correlated to the measured potential during DC interference.
2020
Carbon steel
Cathodic protection
Interference
Monitoring
Polarization
File in questo prodotto:
File Dimensione Formato  
Manuscript - Anodic Interference-03.docx

Accesso riservato

: Pre-Print (o Pre-Refereeing)
Dimensione 1.87 MB
Formato Microsoft Word XML
1.87 MB Microsoft Word XML   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1152418
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 11
social impact