In this chapter it is introduced a simple methodology for the quantitative assessment of the severity of the expected consequences of a tunnel fire that can be applied in any complex environment. The proposed methodology was applied to the Morgex North tunnel to show its potentiality for evaluating the effect of different geometric characteristics on the safety performances of a tunnel in the event of an unwanted fire.
Evaluation of the consequences on the users safety
Borghetti F.;Derudi M.;Gandini P.;Frassoldati A.;Tavelli S.
2017-01-01
Abstract
In this chapter it is introduced a simple methodology for the quantitative assessment of the severity of the expected consequences of a tunnel fire that can be applied in any complex environment. The proposed methodology was applied to the Morgex North tunnel to show its potentiality for evaluating the effect of different geometric characteristics on the safety performances of a tunnel in the event of an unwanted fire.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
Tunnel+Fire+Testing+and+Modeling.pdf
Accesso riservato
:
Publisher’s version
Dimensione
10.08 MB
Formato
Adobe PDF
|
10.08 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.