This paper deals with a multiphysics numerical modelling via finite element method (FEM) of an air-coupled array piezoelectric micromachined ultrasonic transducers (PMUTs). The proposed numerical model is fully 3D with the following features: the presence of the fabrication induced residual stresses, which determine a geometrically non-linear initial deformed configuration of the diaphragms and a remarkable shift of the fundamental frequency; the multiple coupling between didierent physics, namely electro-mechanical-coupling for the piezo-electric model, acoustic-structure interaction at the acoustic-structure interface and pressure acoustics in the surrounding air. The model takes into account the complete set of PMUTs belonging to the silicon die in a 4 x 4 array configuration and the protective package, as well. The results have been validated by experimental data, in terms of initial static pre-deflected configuration of the diaphragms and frequency response function of the PMUT. The numerical procedure was applied, to analyze didierent package configurations of the device, to study the influence of the holes on the acoustic transmission in terms of SPL and propagation pattern and consequently extract a set of design guidelines.

On the effects of package on the PMUTs performances-multiphysics model and frequency analyses

Massimino G.;Colombo A.;Ardito R.;Corigliano A.
2020-01-01

Abstract

This paper deals with a multiphysics numerical modelling via finite element method (FEM) of an air-coupled array piezoelectric micromachined ultrasonic transducers (PMUTs). The proposed numerical model is fully 3D with the following features: the presence of the fabrication induced residual stresses, which determine a geometrically non-linear initial deformed configuration of the diaphragms and a remarkable shift of the fundamental frequency; the multiple coupling between didierent physics, namely electro-mechanical-coupling for the piezo-electric model, acoustic-structure interaction at the acoustic-structure interface and pressure acoustics in the surrounding air. The model takes into account the complete set of PMUTs belonging to the silicon die in a 4 x 4 array configuration and the protective package, as well. The results have been validated by experimental data, in terms of initial static pre-deflected configuration of the diaphragms and frequency response function of the PMUT. The numerical procedure was applied, to analyze didierent package configurations of the device, to study the influence of the holes on the acoustic transmission in terms of SPL and propagation pattern and consequently extract a set of design guidelines.
2020
Acoustic-structure interaction
Array
Flexible package
Multiphysics modelling
Piezoelectric tranducers
Ultrasound
File in questo prodotto:
File Dimensione Formato  
micromachines-11-00307-v2.pdf

accesso aperto

: Publisher’s version
Dimensione 2.55 MB
Formato Adobe PDF
2.55 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1146797
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact