A sealed miniaturized Tissue Equivalent Proportional Counter (mini-TEPC) able to work in gas-steady modality was developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL – INFN, Legnaro, Italy). The aim of the present work is to compare the response of this mini-TEPC with that of a silicon microdosimeter based on a monolithic telescope. Pairwise measurements were performed at the 62 MeV proton clinical Spread Out Bragg Peak (SOBP) of CATANA at the Southern National Laboratories of INFN (LNS – INFN, Catania, Italy). The dose mean lineal energy values were derived from the spectra measured with the two detectors and compared with the total dose-averaged LET calculated by means of Geant4 Monte Carlo simulations. Finally, the possibility to apply the Microdosimetric Kinetic Model (MKM) to reproduce RBE variations with depth along the Spread Out Bragg Peak was investigated.

Microdosimetry with a sealed mini-TEPC and a silicon telescope at a clinical proton SOBP of CATANA

Colautti P.;Bortot D.;Mazzucconi D.;Pola A.;Agosteo S.;
2020-01-01

Abstract

A sealed miniaturized Tissue Equivalent Proportional Counter (mini-TEPC) able to work in gas-steady modality was developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL – INFN, Legnaro, Italy). The aim of the present work is to compare the response of this mini-TEPC with that of a silicon microdosimeter based on a monolithic telescope. Pairwise measurements were performed at the 62 MeV proton clinical Spread Out Bragg Peak (SOBP) of CATANA at the Southern National Laboratories of INFN (LNS – INFN, Catania, Italy). The dose mean lineal energy values were derived from the spectra measured with the two detectors and compared with the total dose-averaged LET calculated by means of Geant4 Monte Carlo simulations. Finally, the possibility to apply the Microdosimetric Kinetic Model (MKM) to reproduce RBE variations with depth along the Spread Out Bragg Peak was investigated.
2020
Beam quality; Microdosimetry; Mini-TEPC; Proton therapy; Silicon telescope
File in questo prodotto:
File Dimensione Formato  
Bianchi_Catana_definitivo.pdf

Accesso riservato

: Publisher’s version
Dimensione 1.78 MB
Formato Adobe PDF
1.78 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1134354
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 26
social impact