The ID32 Soft X-ray Beamline line is an ESRF upgrade beamline for X-ray absorption (XAS) and Resonant Inelastic X-ray Scattering (RIXS) spectroscopic studies. It was opened to Users in October 2014 and provides polarised soft X-rays in the 400–1600 eV energy range. It has two branches: One branch has been designed for X-ray magnetic dichroism experiments, both linear (XMLD) and circular (XMCD), with high sensitivity, reproducibility, flexibility, user friendliness and the capability for fast energy scanning. The X-ray beam is available in two experimental areas, one with a dedicated superconducting high field magnet and a sample preparation facility, the second area being open for User instruments. The other branch is dedicated to very high energy resolution Resonant Inelastic X-ray Scattering experiments with a combined resolving power up to 30 000 around 930 eV. A scattering arm which is continuously variable under UHV vacuum over 100 degrees and a four-circle sample goniometer allows accurate positioning of the sample to enable 3D mapping of q space. Combined with the possibility of polarisation analysis of the outgoing photons the beamline provides a state-of-the-art soft X-ray RIXS facility.

The beamline ID32 at the ESRF for soft X-ray high energy resolution resonant inelastic X-ray scattering and polarisation dependent X-ray absorption spectroscopy

Ghiringhelli G.;Braicovich L.;
2018-01-01

Abstract

The ID32 Soft X-ray Beamline line is an ESRF upgrade beamline for X-ray absorption (XAS) and Resonant Inelastic X-ray Scattering (RIXS) spectroscopic studies. It was opened to Users in October 2014 and provides polarised soft X-rays in the 400–1600 eV energy range. It has two branches: One branch has been designed for X-ray magnetic dichroism experiments, both linear (XMLD) and circular (XMCD), with high sensitivity, reproducibility, flexibility, user friendliness and the capability for fast energy scanning. The X-ray beam is available in two experimental areas, one with a dedicated superconducting high field magnet and a sample preparation facility, the second area being open for User instruments. The other branch is dedicated to very high energy resolution Resonant Inelastic X-ray Scattering experiments with a combined resolving power up to 30 000 around 930 eV. A scattering arm which is continuously variable under UHV vacuum over 100 degrees and a four-circle sample goniometer allows accurate positioning of the sample to enable 3D mapping of q space. Combined with the possibility of polarisation analysis of the outgoing photons the beamline provides a state-of-the-art soft X-ray RIXS facility.
2018
RIXS; Soft X-ray beam line; Spectrometer; Synchrotron radiation; VLS-PGM; XMCD
File in questo prodotto:
File Dimensione Formato  
NIM A 903 175 (Brookes ID32 beam line and ERIXS descriprion).pdf

Accesso riservato

: Publisher’s version
Dimensione 5.67 MB
Formato Adobe PDF
5.67 MB Adobe PDF   Visualizza/Apri
11311-1128322_Ghiringhelli.pdf

Open Access dal 22/09/2020

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 11.9 MB
Formato Adobe PDF
11.9 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1128322
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 84
  • ???jsp.display-item.citation.isi??? 68
social impact