The use of chemical bonds to fasten reinforcement bars in existing concrete structures has been widely developed in the previous years, showing in many cases higher bond values compared to cast in rebars due to better performance of the adhesive mortar. However, at elevated temperatures the concrete-adhesive bond tends to weaken endangering the construction under a fire situation. The paper presents the result of an experimental campaign carried out at Scientific and Technical Center of Building and Politecnico di Milano laboratories on a post-installed connection using vinyl-ester polymer. This paper aims to investigate the behavior of rebar connections through chemical resin when subjected to high temperatures, with particular emphasis on the effects of water vaporization in the concrete and on the influence of heating procedures on the mortar post-curing. Two different pull-out test procedures were adopted, differentiating each other for the loading and heating sequences. Results showed that specimens with the same water content may present different thermal gradients; however, comparable mean temperatures along the bar are detected for the same values of applied load. Moreover, for a given temperature, the increase of bond strength with exposure time showed a convergence towards an asymptotic value.

Effects of different test apparati and heating procedures on the bond properties of post-installed rebar connections under elevated temperatures

Muciaccia G.;
2019-01-01

Abstract

The use of chemical bonds to fasten reinforcement bars in existing concrete structures has been widely developed in the previous years, showing in many cases higher bond values compared to cast in rebars due to better performance of the adhesive mortar. However, at elevated temperatures the concrete-adhesive bond tends to weaken endangering the construction under a fire situation. The paper presents the result of an experimental campaign carried out at Scientific and Technical Center of Building and Politecnico di Milano laboratories on a post-installed connection using vinyl-ester polymer. This paper aims to investigate the behavior of rebar connections through chemical resin when subjected to high temperatures, with particular emphasis on the effects of water vaporization in the concrete and on the influence of heating procedures on the mortar post-curing. Two different pull-out test procedures were adopted, differentiating each other for the loading and heating sequences. Results showed that specimens with the same water content may present different thermal gradients; however, comparable mean temperatures along the bar are detected for the same values of applied load. Moreover, for a given temperature, the increase of bond strength with exposure time showed a convergence towards an asymptotic value.
2019
Post-curing; Post-installed rebar; Pull-out; Water vaporization
File in questo prodotto:
File Dimensione Formato  
template.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 1.9 MB
Formato Adobe PDF
1.9 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1126776
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact