This work aims to investigate about integration of a Dual Active Bridge converter (DAB) developed for MV distribution lines into a traction system of an urban metro railway. Equipment is fed by 1500 V DC catenary and supplies active/passive loads at low voltage (750 V DC), providing galvanic insulation for safety reasons. Operation at very maximum voltage limits (up to 2 kV DC) and in case of MV drops and fluctuations have been simulated, focusing on system stability, control and proper sizing of passive filters to interface the converter with a storage device.
Dual Active Bridge converters for MV distribution lines into 1500 v DC metro railway system
Clerici A.;Gandolfi C.;Brenna M.
2019-01-01
Abstract
This work aims to investigate about integration of a Dual Active Bridge converter (DAB) developed for MV distribution lines into a traction system of an urban metro railway. Equipment is fed by 1500 V DC catenary and supplies active/passive loads at low voltage (750 V DC), providing galvanic insulation for safety reasons. Operation at very maximum voltage limits (up to 2 kV DC) and in case of MV drops and fluctuations have been simulated, focusing on system stability, control and proper sizing of passive filters to interface the converter with a storage device.File in questo prodotto:
Non ci sono file associati a questo prodotto.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.