Magnetic-resonance linear-accelerator (MR-LINAC) systems integrating in-room magnetic-resonance-imaging (MRI) guidance are a currently emerging technology. Such systems address the need to provide frequent imaging at optimal soft-tissue contrast for treatment guidance. However, the use of MRI-guidance in radiotherapy should address imaging-related spatial distortions, which may hinder accurate geometrical characterization of the treatment site. Since spatial encoding relies on well-defined magnetic fields, accurate modeling of the magnetic field alterations due to [Formula: see text]-inhomogeneities, gradient nonlinearities, and susceptibilities is needed. In this work, the modeling of susceptibility induced distortions is considered. Dedicated susceptibility measurements are reported, aiming at extending the characterization of different tissues for MRI-guided extra-cranial radiotherapy applications. A digital 4D anthropomorphic phantom, providing time-resolved anatomical changes due to breathing, is exploited as reference anatomy to quantify spatial distortions due to variations in tissue susceptibility. Sub-millimeter values can be attributed to susceptibility-induced distortions, with maximum values up to 2.3 mm at a gradient strength of 5 mT m-1. Improvements in susceptibility simulation for extra-cranial sites are shown when including specifically the contributions from lung, liver and muscular tissues.

Improving the modelling of susceptibility-induced spatial distortions in MRI-guided extra-cranial radiotherapy

Paganelli C.;Baroni G.;Riboldi M.
2019-01-01

Abstract

Magnetic-resonance linear-accelerator (MR-LINAC) systems integrating in-room magnetic-resonance-imaging (MRI) guidance are a currently emerging technology. Such systems address the need to provide frequent imaging at optimal soft-tissue contrast for treatment guidance. However, the use of MRI-guidance in radiotherapy should address imaging-related spatial distortions, which may hinder accurate geometrical characterization of the treatment site. Since spatial encoding relies on well-defined magnetic fields, accurate modeling of the magnetic field alterations due to [Formula: see text]-inhomogeneities, gradient nonlinearities, and susceptibilities is needed. In this work, the modeling of susceptibility induced distortions is considered. Dedicated susceptibility measurements are reported, aiming at extending the characterization of different tissues for MRI-guided extra-cranial radiotherapy applications. A digital 4D anthropomorphic phantom, providing time-resolved anatomical changes due to breathing, is exploited as reference anatomy to quantify spatial distortions due to variations in tissue susceptibility. Sub-millimeter values can be attributed to susceptibility-induced distortions, with maximum values up to 2.3 mm at a gradient strength of 5 mT m-1. Improvements in susceptibility simulation for extra-cranial sites are shown when including specifically the contributions from lung, liver and muscular tissues.
2019
image guidance; MRI-guided radiotherapy; spatial distortion artefacts; susceptibility
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1119218
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact