In June 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) jointly deployed a pair of coherent 20 GHz and 40 GHz beacon receivers to the POLIMI campus in Milan, Italy to characterize the atmospheric channel at Ka- and Q-band within the framework of the Alphasat experiment. The Milan receivers observe the continuous-wave beacons broadcast over Europe by the Aldo Paraboni Technology Demonstration Payload (TDP #5), and, in September 2017, both channels were upgraded to incorporate a novel digital radiometer (DR) measurement which NASA has recently employed in other propagation measurement campaigns. In November 2016, a co-located water vapor radiometer (WVR) was also installed at POLIMI, and the concurrent data from both the WVR and DR thusly enables validation of this new DR technique against the established WVR. herein, we preliminarily investigate the calibration of the DR measurements using the WVR data and also assess a calibration method that may be implemented where WVR data is not readily available.
Comparison of Integrated Digital Radiometer with Concurrent Water Vapor Radiometer using the Alphasat Receivers in Milan, Italy
Luini, L;Riva, C
2019-01-01
Abstract
In June 2014, NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) jointly deployed a pair of coherent 20 GHz and 40 GHz beacon receivers to the POLIMI campus in Milan, Italy to characterize the atmospheric channel at Ka- and Q-band within the framework of the Alphasat experiment. The Milan receivers observe the continuous-wave beacons broadcast over Europe by the Aldo Paraboni Technology Demonstration Payload (TDP #5), and, in September 2017, both channels were upgraded to incorporate a novel digital radiometer (DR) measurement which NASA has recently employed in other propagation measurement campaigns. In November 2016, a co-located water vapor radiometer (WVR) was also installed at POLIMI, and the concurrent data from both the WVR and DR thusly enables validation of this new DR technique against the established WVR. herein, we preliminarily investigate the calibration of the DR measurements using the WVR data and also assess a calibration method that may be implemented where WVR data is not readily available.File | Dimensione | Formato | |
---|---|---|---|
Comparison of Digital Radiometer with WVR in Milan - EuCAP 2019 - Draft ....pdf
Accesso riservato
Descrizione: Contributo completo
:
Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione
1.83 MB
Formato
Adobe PDF
|
1.83 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.