Precast concrete industrial buildings have been widely spreading over the Italian territory mostly devoted to industrial development after WWII. The pioneering structures built in the early decades of this period have been designed with criteria which are now obsolete and with lower static actions with respect to the actual standards, moreover disregarding any conception of seismic or fire resistance. As such, they are a potential source of strong vulnerability. With reference to a large industrial complex located in Brianza (Northern Italy) built with successive expansions from the ‘40s to the ‘70s, the structural performance indexes associated to static, seismic and fire loads are evaluated for the different classical typologies of that period, including roofs with truss strut-tie systems, restrained arches, and tapered beams. The costs associated to strengthening/retrofitting are also estimated for each typology.

Rehabilitation of early-age precast concrete structures: a feasibility study on an industrial complex progressively built in 1940s-1970s in Northern Italy

B. Dal Lago;V. Krelani;
2019-01-01

Abstract

Precast concrete industrial buildings have been widely spreading over the Italian territory mostly devoted to industrial development after WWII. The pioneering structures built in the early decades of this period have been designed with criteria which are now obsolete and with lower static actions with respect to the actual standards, moreover disregarding any conception of seismic or fire resistance. As such, they are a potential source of strong vulnerability. With reference to a large industrial complex located in Brianza (Northern Italy) built with successive expansions from the ‘40s to the ‘70s, the structural performance indexes associated to static, seismic and fire loads are evaluated for the different classical typologies of that period, including roofs with truss strut-tie systems, restrained arches, and tapered beams. The costs associated to strengthening/retrofitting are also estimated for each typology.
2019
Proceedings of the 7th UBT International Conference on Civil Engineering, Infrastructure and Environment
978-9951-437-73-8
Precast structures, Structural retrofit, Historical, Mechanical connections
File in questo prodotto:
File Dimensione Formato  
Final Paper.pdf

Accesso riservato

Descrizione: Articolo
: Publisher’s version
Dimensione 251.68 kB
Formato Adobe PDF
251.68 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1118530
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact