We have developed a novel method for noncontact measurement of breathing function. The method is based on statistical modeling of dynamic thermal data captured through an infrared imaging system. The expired air has higher temperature than the typical background of indoor environments (e.g., walls). Therefore, the particles of the expired air emit at a higher power than the background, a phenomenon which is captured as a distinct thermal signature in the infrared imagery. There is significant technical difficulty in computing this signature, however, because the phenomenon is of very low intensity and transient nature. We use an advanced statistical algorithm based on the method of moments and the Jeffrey's divergence measure to address the problem. So far, we were able to compute correctly the breathing waveforms for ten (10) subjects at distances ranging from 6-8 feet. The results were checked against concomitant ground-truth data collected with a traditional contact sensor. The technology is expected to find applications in the next generation of touchless polygraphy and in preventive health care.

Touchless monitoring of breathing function

Tsiamyrtzis, Panagiotis
2004-01-01

Abstract

We have developed a novel method for noncontact measurement of breathing function. The method is based on statistical modeling of dynamic thermal data captured through an infrared imaging system. The expired air has higher temperature than the typical background of indoor environments (e.g., walls). Therefore, the particles of the expired air emit at a higher power than the background, a phenomenon which is captured as a distinct thermal signature in the infrared imagery. There is significant technical difficulty in computing this signature, however, because the phenomenon is of very low intensity and transient nature. We use an advanced statistical algorithm based on the method of moments and the Jeffrey's divergence measure to address the problem. So far, we were able to compute correctly the breathing waveforms for ten (10) subjects at distances ranging from 6-8 feet. The results were checked against concomitant ground-truth data collected with a traditional contact sensor. The technology is expected to find applications in the next generation of touchless polygraphy and in preventive health care.
2004
Proceedings of the The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
0-7803-8439-3
File in questo prodotto:
File Dimensione Formato  
Touchless Monitoring of Breathing Function.pdf

Accesso riservato

: Publisher’s version
Dimensione 137.65 kB
Formato Adobe PDF
137.65 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1116523