Introduction. IAQ is one the main topic in which governments are focusing. In architectures for health, several researches are reporting a growing number of data analysis and research works in order to improve users’ health. Nowadays many studies are related to biological and physical risks otherwise chemical ones are less investigated. It determinates the need of guideline values for hospitals because the current scenario lacks of specific norms. Methods. A research group has started a monitoring of IAQ in inpatient rooms, giving rise to a protocol supported by ISO 16000 and international guidelines. The analysis examines VOCs, and the influence of thermos-hygrometric, ventilation and concentration of pollutants’ conditions. Results. The application of the protocol on some inpatient rooms permitted to verify the monitoring feasibility. Each investigation (12 weeks per year) considered all the activities, users and processes that affect IAQ, as well as room configuration. Although data analysis reports quite adequate values, several design and management activities affect the performances and VOC values, especially related to Benzene, Carbon Dioxide, and Formaldehyde. Conclusion. The analysis is expanding to several hospitals. Although the main goal is to reduce the concentration levels, the aim is to define limit values for VOCs, for guaranteeing healthy healing spaces

VOC concentrations in healing environments: a protocol for monitoring activities in inpatient wards and its application on some case studies

Gola, M;Capolongo, S
2019-01-01

Abstract

Introduction. IAQ is one the main topic in which governments are focusing. In architectures for health, several researches are reporting a growing number of data analysis and research works in order to improve users’ health. Nowadays many studies are related to biological and physical risks otherwise chemical ones are less investigated. It determinates the need of guideline values for hospitals because the current scenario lacks of specific norms. Methods. A research group has started a monitoring of IAQ in inpatient rooms, giving rise to a protocol supported by ISO 16000 and international guidelines. The analysis examines VOCs, and the influence of thermos-hygrometric, ventilation and concentration of pollutants’ conditions. Results. The application of the protocol on some inpatient rooms permitted to verify the monitoring feasibility. Each investigation (12 weeks per year) considered all the activities, users and processes that affect IAQ, as well as room configuration. Although data analysis reports quite adequate values, several design and management activities affect the performances and VOC values, especially related to Benzene, Carbon Dioxide, and Formaldehyde. Conclusion. The analysis is expanding to several hospitals. Although the main goal is to reduce the concentration levels, the aim is to define limit values for VOCs, for guaranteeing healthy healing spaces
2019
IAQVEC
iaq, indoor air quality, inpatient room, VOCs
File in questo prodotto:
File Dimensione Formato  
2019_IAQVEC_Settimo_2019_IOP_Conf._Ser.__Mater._Sci._Eng._609_042107.pdf

accesso aperto

: Publisher’s version
Dimensione 553.98 kB
Formato Adobe PDF
553.98 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1114093
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact