Extinction coefficient (ε) is a critical parameter for quantification of oxy-, deoxy-, and total-hemoglobin concentrations (Δ[HbO2], Δ[Hb], Δ[tHb]) from optical measurements of Near-infrared spectroscopy (NIRS). There are several different ε data sets which were frequently used in NIRS quantification. A previous study reported that even a small variation in ε could cause a significant difference in hemodynamic measurements. Apparently the selection of an optimal ε data set is important for NIRS. We conducted oxygen-state-varied and blood-concentration-varied model experiments with 57 human blood samples to mimic tissue hemodynamic variations. Seven reported ε data sets were evaluated by comparisons between quantifications and assumed values. We found that the Moaveni et al (1970)’ ε data set was the optimal one, the NIRS quantification varied significantly among different ε data sets and parameter Δ[tHb] was most sensitive to ε data sets selection.

Optimal hemoglobin extinction coefficient data set for near-infrared spectroscopy

Qiu L.;
2017-01-01

Abstract

Extinction coefficient (ε) is a critical parameter for quantification of oxy-, deoxy-, and total-hemoglobin concentrations (Δ[HbO2], Δ[Hb], Δ[tHb]) from optical measurements of Near-infrared spectroscopy (NIRS). There are several different ε data sets which were frequently used in NIRS quantification. A previous study reported that even a small variation in ε could cause a significant difference in hemodynamic measurements. Apparently the selection of an optimal ε data set is important for NIRS. We conducted oxygen-state-varied and blood-concentration-varied model experiments with 57 human blood samples to mimic tissue hemodynamic variations. Seven reported ε data sets were evaluated by comparisons between quantifications and assumed values. We found that the Moaveni et al (1970)’ ε data set was the optimal one, the NIRS quantification varied significantly among different ε data sets and parameter Δ[tHb] was most sensitive to ε data sets selection.
2017
(120.0120) Instrumentation, measurement, and metrology; (170.1470) Blood or tissue constituent monitoring; (170.6510) Spectroscopy
File in questo prodotto:
File Dimensione Formato  
boe-8-11-5151.pdf

Accesso riservato

Descrizione: Fulltext
: Publisher’s version
Dimensione 3.05 MB
Formato Adobe PDF
3.05 MB Adobe PDF   Visualizza/Apri
Extinction coefficient_revised_ combine.pdf

accesso aperto

Descrizione: Fulltext
: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 935.49 kB
Formato Adobe PDF
935.49 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1090827
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 45
social impact