Purpose: To introduce a novel modality that enables the measurement of forces applied during a transalveolar sinus floor elevation (tSFE) and to investigate the influence of anatomical and surgical factors on the necessitated force in sinus membrane detachment. Material and Methods: A new endosinus probe, innovated with a calibrated load cell, was used to test the forces needed to perforate ten maxillary sinuses in 5 human cadavers. The same probe was also used to detach the Schneiderian membrane from the bony floor of 21 human subjects undergoing tSFE. Results: The force needed to cause membrane perforation in the cadaver sample was on average 3.46 ± 1.04 N. The maximum force applied in vivo to a sinus membrane without perforation was 2.01 ± 0.67 N on average. Regression analysis showed that smoking (P < 0.001), as well as 3.0 mm osteotomy (P < 0.001), was significantly correlated to increased forces during membrane detachment. Conclusions: The maximum force needed to detach the membrane was found to be, on average, lower than the membrane breaking load in cadavers. Furthermore, because of smoking and a 3.0-mm osteotomy diameter demonstrating a high association with increased forces during membrane detachment, they may be considered as risk factors of membrane perforation.

Analysis of forces applied during transalveolar sinus lift: A preliminary clinical study

Zappa E.;
2018-01-01

Abstract

Purpose: To introduce a novel modality that enables the measurement of forces applied during a transalveolar sinus floor elevation (tSFE) and to investigate the influence of anatomical and surgical factors on the necessitated force in sinus membrane detachment. Material and Methods: A new endosinus probe, innovated with a calibrated load cell, was used to test the forces needed to perforate ten maxillary sinuses in 5 human cadavers. The same probe was also used to detach the Schneiderian membrane from the bony floor of 21 human subjects undergoing tSFE. Results: The force needed to cause membrane perforation in the cadaver sample was on average 3.46 ± 1.04 N. The maximum force applied in vivo to a sinus membrane without perforation was 2.01 ± 0.67 N on average. Regression analysis showed that smoking (P < 0.001), as well as 3.0 mm osteotomy (P < 0.001), was significantly correlated to increased forces during membrane detachment. Conclusions: The maximum force needed to detach the membrane was found to be, on average, lower than the membrane breaking load in cadavers. Furthermore, because of smoking and a 3.0-mm osteotomy diameter demonstrating a high association with increased forces during membrane detachment, they may be considered as risk factors of membrane perforation.
2018
Cadaver; Humans; Maxillary sinus; Osteotomy; Risk factors; Sinus floor augmentation; Aged; Female; Humans; Male; Maxillary Sinus; Middle Aged; Stress, Mechanical; Sinus Floor Augmentation
File in questo prodotto:
File Dimensione Formato  
IMPLANT DENTISTRY.pdf

Accesso riservato

Descrizione: Paper
: Publisher’s version
Dimensione 368.62 kB
Formato Adobe PDF
368.62 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1088808
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact