In this work, the opportunities provided by dynamic identification techniques for non-destructive evaluation of heritage structures are discussed with a focus on different bell towers, located in the Ferrara Province (Italy). All of them were stricken by a long seismic sequence (Emilia Romagna, North-East of Italy, May-June 2012 seismic sequence) and they are investigated in detail to have an insight into their dynamic behaviour. Furthermore, the experimental investigations and the operational modal analysis results are presented and they are useful for defining the Finite Element (FE) models of the towers within a continuum approach. The monitoring system consists of several sensors properly connected. The positioning of the instrumentation has been conditioned by many operative problems due to the limited accessibility of the structures, both related to the main access and to reaching the top. However, it has been possible to identify with a certain confidence the first three frequencies of the towers and their corresponding mode shapes. The results carried out after the FE updating procedure may be considered very good. The material data values estimated in this way will constitute an important reference for the evaluation of the state of the building.

Numerical model upgrading of ancient bell towers monitored with a wired sensors network

Milani, G.;Lenci, S.
2018-01-01

Abstract

In this work, the opportunities provided by dynamic identification techniques for non-destructive evaluation of heritage structures are discussed with a focus on different bell towers, located in the Ferrara Province (Italy). All of them were stricken by a long seismic sequence (Emilia Romagna, North-East of Italy, May-June 2012 seismic sequence) and they are investigated in detail to have an insight into their dynamic behaviour. Furthermore, the experimental investigations and the operational modal analysis results are presented and they are useful for defining the Finite Element (FE) models of the towers within a continuum approach. The monitoring system consists of several sensors properly connected. The positioning of the instrumentation has been conditioned by many operative problems due to the limited accessibility of the structures, both related to the main access and to reaching the top. However, it has been possible to identify with a certain confidence the first three frequencies of the towers and their corresponding mode shapes. The results carried out after the FE updating procedure may be considered very good. The material data values estimated in this way will constitute an important reference for the evaluation of the state of the building.
2018
Proceedings of the International Masonry Society Conferences
Case Study; Cultural Heritage; Structural Health Monitoring; Tower; Vibration; Building and Construction; Materials Science (miscellaneous)
File in questo prodotto:
File Dimensione Formato  
2018_10IMC_Pierdicca_Clementi_Milani.pdf

Accesso riservato

Descrizione: 2018_Clementi_Pierdicca_Milani
: Publisher’s version
Dimensione 1.93 MB
Formato Adobe PDF
1.93 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1087161
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 32
  • ???jsp.display-item.citation.isi??? ND
social impact