CSYP (CYlindrical SPectrometer) is a directional neutron spectrometer based on a single moderator embedding multiple thermal neutron detectors. Similarly to Bonner Spheres, CYSP responds from thermal up to GeV neutrons and the spectrum is obtained via few-channel unfolding methods. CYSP has the shape of a polyethylene cylinder with diameter 50 cm and height 65 cm. Owing on a thick collimator and on a specifically designed shielding structure, the internal detectors only respond to neutrons coming from a known direction. Internal thermal neutron detectors are one-cm 2 6 LiF-covered silicon diodes. Un upgraded version of CYPS was developed to work in low intensity applications, such as cosmic field measurements. It is called CYSP-HS (High-Sensitivity) and is equipped with large area 6 LiF-covered silicon diodes (LATND, Large Area Thermal Neutron Detectors). Compared with the former CYSP, the sensitivity increased approximately by an order of magnitude. This paper presents CYSP-HS focusing on the new internal detectors, the response matrix and its verification in a reference field of Am-Be available at the Politecnico di Milano.

CYSP-HS: A new version of the CYSP directional neutron spectrometer with increased sensitivity

Pola, A.;
2018-01-01

Abstract

CSYP (CYlindrical SPectrometer) is a directional neutron spectrometer based on a single moderator embedding multiple thermal neutron detectors. Similarly to Bonner Spheres, CYSP responds from thermal up to GeV neutrons and the spectrum is obtained via few-channel unfolding methods. CYSP has the shape of a polyethylene cylinder with diameter 50 cm and height 65 cm. Owing on a thick collimator and on a specifically designed shielding structure, the internal detectors only respond to neutrons coming from a known direction. Internal thermal neutron detectors are one-cm 2 6 LiF-covered silicon diodes. Un upgraded version of CYPS was developed to work in low intensity applications, such as cosmic field measurements. It is called CYSP-HS (High-Sensitivity) and is equipped with large area 6 LiF-covered silicon diodes (LATND, Large Area Thermal Neutron Detectors). Compared with the former CYSP, the sensitivity increased approximately by an order of magnitude. This paper presents CYSP-HS focusing on the new internal detectors, the response matrix and its verification in a reference field of Am-Be available at the Politecnico di Milano.
2018
CYPS-HS; CYSP; Directional spectrometry; NESCOFI; NEURAPID; Neutron dosimetry; Neutron spectrometry; Single-moderator; Radiation
File in questo prodotto:
File Dimensione Formato  
2018-CISP-HS_Bedogni_et al.pdf

Accesso riservato

Descrizione: Articolo principale
: Publisher’s version
Dimensione 648.01 kB
Formato Adobe PDF
648.01 kB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1085281
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact