A microfluidic flow-based platform (μFP), able to stimulate platelets via exposure of shear stress patterns pertinent to cardiovascular devices and prostheses, was compared to the Hemodynamic Shearing Device (HSD) - a state-of-the-art bench-top system for exposure of platelets to defined levels and patterns of shear. Platelets were exposed to time-varying shear stress patterns in the two systems; in detail, platelets were recirculated in the μFP or stimulated in the HSD to replicate comparable exposure time. Shear-mediated platelet activation was evaluated via (i) the platelet activity state assay, allowing the measurement of platelet-mediated thrombin generation and associated prothrombotic tendencies, (ii) scanning electron microscopy to evaluate morphological changes of sheared platelets, and (iii) flow cytometry for the determination of platelet phosphatidylserine exposure as a marker of shear activation. The results revealed good matching and comparability between the two systems, with similar trends of platelet activation, formation of microaggregates, and analogous trends of activation marker exposure for both the HSD and microfluidic-stimulated samples. These findings support future translation of the microfluidic platform as a Point-of-Care facsimile system for the diagnosis of thrombotic risk in patients implanted with cardiovascular devices.

Microfluidic flow-based platforms for induction and analysis of dynamic shear-mediated platelet activation - Initial validation versus the standardized hemodynamic shearing device

Dimasi, Annalisa;Consolo, Filippo;Rasponi, Marco;Fiore, Gianfranco B.;Redaelli, Alberto
2018-01-01

Abstract

A microfluidic flow-based platform (μFP), able to stimulate platelets via exposure of shear stress patterns pertinent to cardiovascular devices and prostheses, was compared to the Hemodynamic Shearing Device (HSD) - a state-of-the-art bench-top system for exposure of platelets to defined levels and patterns of shear. Platelets were exposed to time-varying shear stress patterns in the two systems; in detail, platelets were recirculated in the μFP or stimulated in the HSD to replicate comparable exposure time. Shear-mediated platelet activation was evaluated via (i) the platelet activity state assay, allowing the measurement of platelet-mediated thrombin generation and associated prothrombotic tendencies, (ii) scanning electron microscopy to evaluate morphological changes of sheared platelets, and (iii) flow cytometry for the determination of platelet phosphatidylserine exposure as a marker of shear activation. The results revealed good matching and comparability between the two systems, with similar trends of platelet activation, formation of microaggregates, and analogous trends of activation marker exposure for both the HSD and microfluidic-stimulated samples. These findings support future translation of the microfluidic platform as a Point-of-Care facsimile system for the diagnosis of thrombotic risk in patients implanted with cardiovascular devices.
2018
Molecular Biology; Materials Science (all); Genetics; Condensed Matter Physics; Physical and Theoretical Chemistry
File in questo prodotto:
File Dimensione Formato  
AS6311978268262441527500697517_content_1.pdf

Open Access dal 23/05/2019

Descrizione: Articolo principale
: Publisher’s version
Dimensione 3.24 MB
Formato Adobe PDF
3.24 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1063634
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact