In the seismic retrofitting of historic churches, the realization of new foundations of collapsed elements represents an important aspect either for the interaction with the underground pre-existing parts or with the new structural elements to be rebuilt. For the specific case study of the Basilica di Collemaggio, after an accurate geometrical survey and on-site geotechnical tests, a specific mixed structure foundation system is proposed in order to fulfill the seismic safety requirements and the Cultural Heritage Office’s conservation prescriptions. Nonlinear analyses are performed considering the interaction between the soil and the foundation system, together with the new interaction between the main pillars and the triumphal arch. The analyses aimed to verify the capabilities of the new foundation system to bear the transversal seismic actions. The analyses are also completed by some experimental tests on the micropiles, which represent the main underground-to-elevation connection elements.

THE NEW FOUNDATION SYSTEM FOR THE TRANSEPT RECONSTRUCTION OF THE BASILICA DI COLLEMAGGIO

M. Zucca;A. Franchi;P. Crespi;N. Longarini;P. Ronca
2018-01-01

Abstract

In the seismic retrofitting of historic churches, the realization of new foundations of collapsed elements represents an important aspect either for the interaction with the underground pre-existing parts or with the new structural elements to be rebuilt. For the specific case study of the Basilica di Collemaggio, after an accurate geometrical survey and on-site geotechnical tests, a specific mixed structure foundation system is proposed in order to fulfill the seismic safety requirements and the Cultural Heritage Office’s conservation prescriptions. Nonlinear analyses are performed considering the interaction between the soil and the foundation system, together with the new interaction between the main pillars and the triumphal arch. The analyses aimed to verify the capabilities of the new foundation system to bear the transversal seismic actions. The analyses are also completed by some experimental tests on the micropiles, which represent the main underground-to-elevation connection elements.
2018
10th IMC ‐ Proceedings of the 10th International Masonry Conference
Foundation system, Historical building, Seismic retrofitting
File in questo prodotto:
File Dimensione Formato  
10th IMC conference proceedings.pdf

Accesso riservato

Descrizione: Atti_Convegno
Dimensione 250.23 MB
Formato Adobe PDF
250.23 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.