The Timed Up and Go test (TUG) is used to assess individual mobility. It evaluates static and dynamic balance by means of the total time required to complete the test, usually measured by a stopwatch. In recent years tools based on portable inertial measurement units (IMU) for clinical application are increasingly available on the market. More specifically, a tool (hardware and dedicated software) to quantify the TUG test based on IMU is now available. However, it has not yet been validated in subjects with Parkinson's disease (PD). Thus, the aim of this study is to compare measurements from instrumented TUG tests (or iTUG) acquired by an IMU with those obtained using an optoelectronic system (the gold standard) and by a stopwatch, to gain an in-depth understanding of IMU behavior in computing iTUG in subjects with PD. To do this, three TUG test trials were carried out on 30 subjects with PD and measured with all three systems simultaneously. System agreements were evaluated using Intraclass Correlation Coefficient and Bland-Altman plots. The device tested showed excellent reliability, accuracy and precision in quantifying total TUG test duration. Since TUG is a widely used test in rehabilitation settings, its automatic quantification through IMUs could potentially improve the quality of assessments in the quantification of PD gait ability.
Timed Up and Go evaluation with wearable devices: Validation in Parkinson's disease
Kleiner, Ana Francisca Rozin;Pacifici, Ilaria;Vagnini, Alessandro;Galli, Manuela
2018-01-01
Abstract
The Timed Up and Go test (TUG) is used to assess individual mobility. It evaluates static and dynamic balance by means of the total time required to complete the test, usually measured by a stopwatch. In recent years tools based on portable inertial measurement units (IMU) for clinical application are increasingly available on the market. More specifically, a tool (hardware and dedicated software) to quantify the TUG test based on IMU is now available. However, it has not yet been validated in subjects with Parkinson's disease (PD). Thus, the aim of this study is to compare measurements from instrumented TUG tests (or iTUG) acquired by an IMU with those obtained using an optoelectronic system (the gold standard) and by a stopwatch, to gain an in-depth understanding of IMU behavior in computing iTUG in subjects with PD. To do this, three TUG test trials were carried out on 30 subjects with PD and measured with all three systems simultaneously. System agreements were evaluated using Intraclass Correlation Coefficient and Bland-Altman plots. The device tested showed excellent reliability, accuracy and precision in quantifying total TUG test duration. Since TUG is a widely used test in rehabilitation settings, its automatic quantification through IMUs could potentially improve the quality of assessments in the quantification of PD gait ability.File | Dimensione | Formato | |
---|---|---|---|
Kleiner JoBand M Therapies .pdf
Accesso riservato
Dimensione
542.5 kB
Formato
Adobe PDF
|
542.5 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.