Given the high energy saving potential obtainable from windows retrofitting, such measures are frequently implemented in the case of historic and heritage buildings. However, often, fenestration retrofitting is interpreted as windows replacement. Rarely is the energy saving potential allowed by windows maintenance or nondestructive measures investigated. Even more rarely, the validity of retrofitting measures is assessed in the long term considering their performance obsolescence. In this study, the Life Cycle (LC) operating energy saving potential allowed by different retrofitting options -from windows maintenance to total replacement- is discussed with regard to a heritage building in Antwerp. The study evidences that if taking into account the retrofitting interventions technical obsolescence, instead of assuming constant the technical performance throughout the retrofitting Service Life (SL), the results significantly vary. This adds a methodological concern to be considered during retrofitting design and evaluation. The results pointed out that performing basic fenestration maintenance enables in itself Life Cycle (LC) operating energy savings. Moreover, it was evidenced that, destructive retrofitting techniques, such as windows replacement, not necessarily allow for the largest energy savings. Indeed the installation of single or double glazed internal windows may allow for similar or even more significant savings

Life cycle operating energy saving from windows retrofitting in heritage buildings accounting for technical performance decay

M. Lavagna
2018-01-01

Abstract

Given the high energy saving potential obtainable from windows retrofitting, such measures are frequently implemented in the case of historic and heritage buildings. However, often, fenestration retrofitting is interpreted as windows replacement. Rarely is the energy saving potential allowed by windows maintenance or nondestructive measures investigated. Even more rarely, the validity of retrofitting measures is assessed in the long term considering their performance obsolescence. In this study, the Life Cycle (LC) operating energy saving potential allowed by different retrofitting options -from windows maintenance to total replacement- is discussed with regard to a heritage building in Antwerp. The study evidences that if taking into account the retrofitting interventions technical obsolescence, instead of assuming constant the technical performance throughout the retrofitting Service Life (SL), the results significantly vary. This adds a methodological concern to be considered during retrofitting design and evaluation. The results pointed out that performing basic fenestration maintenance enables in itself Life Cycle (LC) operating energy savings. Moreover, it was evidenced that, destructive retrofitting techniques, such as windows replacement, not necessarily allow for the largest energy savings. Indeed the installation of single or double glazed internal windows may allow for similar or even more significant savings
2018
Windows retrofitting, building dynamic simulations Technical performance decay modelling Durability Infrared thermography Blower door test Life cycle operating energy saving
File in questo prodotto:
File Dimensione Formato  
2018 JBE Litti LCE windows decay.pdf

Accesso riservato

: Publisher’s version
Dimensione 1.73 MB
Formato Adobe PDF
1.73 MB Adobe PDF   Visualizza/Apri
11311-1050526 Lavagna.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 2 MB
Formato Adobe PDF
2 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1050526
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 26
social impact