This paper presents a metrological characterization study of SICK LMS 511 laser scanner, with an extended analysis of its main acquisition issues. Various parameters that could affect the sensor performances, such as warm-up time, target properties (color and material), and target position (distance and orientation) are investigated. Moreover, the mixed pixel problem is introduced and, finally, since the sensor is designed to work in a wide outdoor environment, the effect of direct sun light is taken into account. Some cases of faulty data are identified and explanations discussed.
Characterization of a 2-D laser scanner for outdoor wide range measurement
CANCIANI, EUGENIO;Vandone, A.;Sala, R.
2015-01-01
Abstract
This paper presents a metrological characterization study of SICK LMS 511 laser scanner, with an extended analysis of its main acquisition issues. Various parameters that could affect the sensor performances, such as warm-up time, target properties (color and material), and target position (distance and orientation) are investigated. Moreover, the mixed pixel problem is introduced and, finally, since the sensor is designed to work in a wide outdoor environment, the effect of direct sun light is taken into account. Some cases of faulty data are identified and explanations discussed.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
2015 Characterization of a 2-D laser scanner for outdoor wide range measurement.pdf
accesso aperto
:
Publisher’s version
Dimensione
1.45 MB
Formato
Adobe PDF
|
1.45 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.