The paper deals with the development and testing of an innovative code for the performance prediction of solar trough based CSP plants in off-design conditions. The code is developed in MS Visual Basic 6 0 with Excel as user interface The proposed code originates from a previously presented algorithm for on-design sizing and cost estimation of the solar field lay-out, as well as of the main components of the plant, including connecting piping and the steam cycle Off-design calculation starts from data obtained through the on-design algorithm and considers steady-state situations. Both models are implemented in the same software, named PATTO (PArabolic Trough Thermodynamic Optimization), which is very flexible the optical-thermal model of collectors can simulate different kinds of parabolic trough systems in commerce, including a combination of various mirrors, receivers and supports The code is also flexible in terms of working fluid, temperature and pressure range, and can also simulate duce( steam generation plants (DSG) Regarding the power block, a conventional steam cycle with super-heater, eventually a re-heater section, and up to seven regenerative bleedings is adopted. The off-design model calculates thermal performance of collectors taking Into account proper correlations for convective heat transfer coefficients, considering also boiling regime in DSG configurations. Solar plant heat and mass balances and performances at off-design conditions are estimated by accounting for the constraints imposed by the available heat transfer areas in heat exchangers and condenser, as well as the characteristic curve of the steam turbine The numerical model can be used for a single calculation in a specific off-design condition, as well as for a whole year estimation of energy balances with an hourly resolutionThe model is tested towards real applications and reference values found in literature, in particular, focusing on SECS VI plant in the USA and SAM (R) code Annual energy balances with ambient condition taken from TMY3 database are obtained, showing good accuracy of predicted performances. The code potentiality in the design process reveals twofold: it can be used for plant optimization in feasibility studies, moreover it is useful to find the best control strategy of a plant, especially the mass flow of heat transfer fluid in each operating condition

A NUMERICAL MODEL FOR OFF-DESIGN PERFORMANCE CALCULATION OF PARABOLIC TROUGH BASED SOLAR POWER PLANTS

Giostri, A;Saccilotto, C;Silva, P;Macchi, E;Manzolini, G
2010-01-01

Abstract

The paper deals with the development and testing of an innovative code for the performance prediction of solar trough based CSP plants in off-design conditions. The code is developed in MS Visual Basic 6 0 with Excel as user interface The proposed code originates from a previously presented algorithm for on-design sizing and cost estimation of the solar field lay-out, as well as of the main components of the plant, including connecting piping and the steam cycle Off-design calculation starts from data obtained through the on-design algorithm and considers steady-state situations. Both models are implemented in the same software, named PATTO (PArabolic Trough Thermodynamic Optimization), which is very flexible the optical-thermal model of collectors can simulate different kinds of parabolic trough systems in commerce, including a combination of various mirrors, receivers and supports The code is also flexible in terms of working fluid, temperature and pressure range, and can also simulate duce( steam generation plants (DSG) Regarding the power block, a conventional steam cycle with super-heater, eventually a re-heater section, and up to seven regenerative bleedings is adopted. The off-design model calculates thermal performance of collectors taking Into account proper correlations for convective heat transfer coefficients, considering also boiling regime in DSG configurations. Solar plant heat and mass balances and performances at off-design conditions are estimated by accounting for the constraints imposed by the available heat transfer areas in heat exchangers and condenser, as well as the characteristic curve of the steam turbine The numerical model can be used for a single calculation in a specific off-design condition, as well as for a whole year estimation of energy balances with an hourly resolutionThe model is tested towards real applications and reference values found in literature, in particular, focusing on SECS VI plant in the USA and SAM (R) code Annual energy balances with ambient condition taken from TMY3 database are obtained, showing good accuracy of predicted performances. The code potentiality in the design process reveals twofold: it can be used for plant optimization in feasibility studies, moreover it is useful to find the best control strategy of a plant, especially the mass flow of heat transfer fluid in each operating condition
2010
4th International Conference on Energy Sustainability
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1049341
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 0
social impact