Integrity and operational reliability of pipelines requires a continuous monitoring, able to detect, in real time, failure, sabotage and leak of fluids (e.g. natural gas, crude oil, water, products), and to protect the safety of personnel and local communities. In the framework of a research project, eni has developed a proprietary pipeline monitoring technology based on vibroacoustic (negative pressure wave) sensing. This paper presents some experimental and theoretical activities for the evaluation of the system performance versus fluid leaks, in terms of maximum detection distance and sensitivity. The field scenario is a 12 km, 3 inch inner diameter sealine in south of Italy, conveying a fluxing agent from an onshore terminal to an offshore platform. Leak-like events have been produced by opening discharge valves at the terminals. The associated travelling pressure transient, recorded by several monitoring stations, has been compared with the environmental noise (generated by the flow regulation equipment) and with the theoretical models. The predicted propagation parameters and maximum detection distance are in very good agreement with the measured ones: this allows us to use the theoretical simulator for design and performance evaluation of new installations.

Performance of vibroacoustic technology for pipeline leak detection

BERNASCONI, GIANCARLO;
2016-01-01

Abstract

Integrity and operational reliability of pipelines requires a continuous monitoring, able to detect, in real time, failure, sabotage and leak of fluids (e.g. natural gas, crude oil, water, products), and to protect the safety of personnel and local communities. In the framework of a research project, eni has developed a proprietary pipeline monitoring technology based on vibroacoustic (negative pressure wave) sensing. This paper presents some experimental and theoretical activities for the evaluation of the system performance versus fluid leaks, in terms of maximum detection distance and sensitivity. The field scenario is a 12 km, 3 inch inner diameter sealine in south of Italy, conveying a fluxing agent from an onshore terminal to an offshore platform. Leak-like events have been produced by opening discharge valves at the terminals. The associated travelling pressure transient, recorded by several monitoring stations, has been compared with the environmental noise (generated by the flow regulation equipment) and with the theoretical models. The predicted propagation parameters and maximum detection distance are in very good agreement with the measured ones: this allows us to use the theoretical simulator for design and performance evaluation of new installations.
2016
Proceedings of the International Conference on Ocean, Offshore Mechanics and Arctic Engineering - OMAE
9780791849965
Energy Engineering and Power Technology
pipeline monitoring
mechanical engineering
File in questo prodotto:
File Dimensione Formato  
ASMEOMAE2016-54181.pdf

Accesso riservato

: Publisher’s version
Dimensione 1.3 MB
Formato Adobe PDF
1.3 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1039107
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 0
social impact