Distributed real-time systems often rely on clock synchronization. However, the achievement of precise synchronization in Wireless Sensor Networks (WSNs) is hampered by competing design challenges, which finally causes many WSN hardware platforms to rely on low frequency clock crystal for local timebase provision. Although this solution is inexpensive and with a remarkably low energy consumption, it limits the resolution at which time can be measured. The FLOPSYNC synchronization scheme was then introduced to compensate for possible quartz crystal imperfections. The main limitation of FLOPSYNC is that it does not account for the effects of quantization. In this paper we propose a switched control variant of the base FLOPSYNC scheme to address quantization explicitly in the compensator design, providing clock synchronization in cost-sensitive WSN node platforms with a minimal additional overhead. Experimental evidence is given that the approach reaches a synchronization error of at most 1 clock tick in a real WSN.

FLOPSYNC-QACS: Quantization-aware clock synchronization for wireless sensor networks

Terraneo, Federico;Papadopoulos, Alessandro Vittorio;Leva, Alberto;Prandini, Maria
2017-01-01

Abstract

Distributed real-time systems often rely on clock synchronization. However, the achievement of precise synchronization in Wireless Sensor Networks (WSNs) is hampered by competing design challenges, which finally causes many WSN hardware platforms to rely on low frequency clock crystal for local timebase provision. Although this solution is inexpensive and with a remarkably low energy consumption, it limits the resolution at which time can be measured. The FLOPSYNC synchronization scheme was then introduced to compensate for possible quartz crystal imperfections. The main limitation of FLOPSYNC is that it does not account for the effects of quantization. In this paper we propose a switched control variant of the base FLOPSYNC scheme to address quantization explicitly in the compensator design, providing clock synchronization in cost-sensitive WSN node platforms with a minimal additional overhead. Experimental evidence is given that the approach reaches a synchronization error of at most 1 clock tick in a real WSN.
2017
Clock synchronization; Quantized control; Switched control; Wireless sensor network; Software; Hardware and Architecture
File in questo prodotto:
File Dimensione Formato  
2017-QuantisedFLOPSYNC-JSA-post.pdf

Open Access dal 01/11/2019

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 348.93 kB
Formato Adobe PDF
348.93 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1035673
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact