The exact delay-zero calibration in an attosecond pump-probe experiment is important for the correct interpretation of experimental data. In attosecond transient absorption spectroscopy the determination of the delay-zero exclusively from the experimental results is not straightforward and may introduce significant errors. Here, we report the observation of quarter-laser-cycle (4ω) oscillations in a transient absorption experiment in helium using an attosecond pulse train overlapped with a precisely synchronized, moderately strong infrared pulse. We demonstrate how to extract and calibrate the delay-zero with the help of the highly nonlinear 4ω signal. A comparison with the solution of the time-dependent Schrödinger equation is used to confirm the accuracy and validity of the approach. Moreover, we study the mechanisms behind the quarter-laser-cycle and the better-known half-laser-cycle oscillations as a function of experimental parameters. This investigation yields an indication of the robustness of our delay-zero calibration approach.

Multiphoton transitions for delay-zero calibration in attosecond spectroscopy

LUCCHINI, MATTEO;
2015-01-01

Abstract

The exact delay-zero calibration in an attosecond pump-probe experiment is important for the correct interpretation of experimental data. In attosecond transient absorption spectroscopy the determination of the delay-zero exclusively from the experimental results is not straightforward and may introduce significant errors. Here, we report the observation of quarter-laser-cycle (4ω) oscillations in a transient absorption experiment in helium using an attosecond pulse train overlapped with a precisely synchronized, moderately strong infrared pulse. We demonstrate how to extract and calibrate the delay-zero with the help of the highly nonlinear 4ω signal. A comparison with the solution of the time-dependent Schrödinger equation is used to confirm the accuracy and validity of the approach. Moreover, we study the mechanisms behind the quarter-laser-cycle and the better-known half-laser-cycle oscillations as a function of experimental parameters. This investigation yields an indication of the robustness of our delay-zero calibration approach.
2015
attosecond transient absorption spectroscopy; multiphoton ionization; ultrafast spectroscopy; Physics and Astronomy (all)
File in questo prodotto:
File Dimensione Formato  
11311-1027389_Lucchini.pdf

accesso aperto

: Publisher’s version
Dimensione 1.84 MB
Formato Adobe PDF
1.84 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1027389
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact