A closed-loop pulsating heat pipe made of a copper tube (1.1 mm/2 mm I.D./O.D.) and filled with FC-72 has been tested in a large-diameter centrifuge (LDC) of the European Space Agency in Noordwijk at different hypergravity levels up to 20 g, different heat input levels, and different orientations with respect to the gravity direction (vertical bottom heated and horizontal position).The results show that both in the horizontal and vertical orientation the device operation depends on the combined effect of gravity and heat input level. For the horizontal orientation, fluid tratification and the consequent thermal crisis occur at different acceleration levels depending also on the heat input power level and on the heating/gravity history. During the vertical operation, the pulsating heat pipe (PHP) thermal performance is slightly enhanced by the lower hypergravity levels (up to 3 g at 50 W, up to 4 g at 70 W, and up to 6g at 100 W), while two different local thermal crises affect the PHP thermal behavior at higher acceleration levels.

PULSATING HEAT PIPE IN HYPERGRAVITY CONDITIONS

MANZONI, MIRIAM;ARANEO, LUCIO TIZIANO;
2015-01-01

Abstract

A closed-loop pulsating heat pipe made of a copper tube (1.1 mm/2 mm I.D./O.D.) and filled with FC-72 has been tested in a large-diameter centrifuge (LDC) of the European Space Agency in Noordwijk at different hypergravity levels up to 20 g, different heat input levels, and different orientations with respect to the gravity direction (vertical bottom heated and horizontal position).The results show that both in the horizontal and vertical orientation the device operation depends on the combined effect of gravity and heat input level. For the horizontal orientation, fluid tratification and the consequent thermal crisis occur at different acceleration levels depending also on the heat input power level and on the heating/gravity history. During the vertical operation, the pulsating heat pipe (PHP) thermal performance is slightly enhanced by the lower hypergravity levels (up to 3 g at 50 W, up to 4 g at 70 W, and up to 6g at 100 W), while two different local thermal crises affect the PHP thermal behavior at higher acceleration levels.
2015
two-phase flow, pulsating heat pipe, hypergravity, large-diameter centrifuge
File in questo prodotto:
File Dimensione Formato  
HPST-13605-2 final.pdf

Accesso riservato

Descrizione: Paper - PULSATING HEAT PIPE IN HYPERGRAVITY CONDITIONS
: Publisher’s version
Dimensione 888.1 kB
Formato Adobe PDF
888.1 kB Adobe PDF   Visualizza/Apri
Pulsating heat pipe in hypergravity conditions_11311-1013199_Araneo.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 938.99 kB
Formato Adobe PDF
938.99 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1013199
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact