The paper presents the seismic vulnerability analysis of the military dry dock built in 1861 inside the Messina’s harbor. The study appears very important not only for the relevance of the dry dock itself, but also for its social, military and symbolic role. As a first step, the historical documentation about the dry dock delivered by the Military Technical Office, in charge of its maintenance, was thoroughly examined. This activity was fundamental to understand the construction methods, the rehabilitation works executed after the severe earthquake of 1908 and, finally, the works carried out to increase the size of the dry dock in 1950. After this first step, numerical seismic analyses were done with some implemented finite element models (FEM) of the structure. In each FEM, the vertical loads were applied according to the “construction stages” analysis technique, in order to achieve an appropriate representation of the soil stresses around the structure. The analysis results were evaluated according to the Italian design code (NTC 2008) in order to determine the seismic vulnerability of the dry dock.

SEISMIC VULNERABILITY ASSESSMENT OF AN ITALIAN HISTORICAL MASONRY DRY DOCK

ZUCCA, MARCO;CRESPI, PIETRO GIUSEPPE;LONGARINI, NICOLA
2017-01-01

Abstract

The paper presents the seismic vulnerability analysis of the military dry dock built in 1861 inside the Messina’s harbor. The study appears very important not only for the relevance of the dry dock itself, but also for its social, military and symbolic role. As a first step, the historical documentation about the dry dock delivered by the Military Technical Office, in charge of its maintenance, was thoroughly examined. This activity was fundamental to understand the construction methods, the rehabilitation works executed after the severe earthquake of 1908 and, finally, the works carried out to increase the size of the dry dock in 1950. After this first step, numerical seismic analyses were done with some implemented finite element models (FEM) of the structure. In each FEM, the vertical loads were applied according to the “construction stages” analysis technique, in order to achieve an appropriate representation of the soil stresses around the structure. The analysis results were evaluated according to the Italian design code (NTC 2008) in order to determine the seismic vulnerability of the dry dock.
2017
Dry dock, Seismic vulnerability, Earthquake, Finite element analysis
File in questo prodotto:
File Dimensione Formato  
Masonry dry dock_CS EngStruct.pdf

accesso aperto

: Publisher’s version
Dimensione 1.43 MB
Formato Adobe PDF
1.43 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1011598
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? ND
social impact