This paper presents the principle and complete characterization of a single-chip unit formed by microelectromechanical system magnetometers to sense the 3-D magnetic field vector and a Tang resonator. The three sensors, nominally with the same resonance frequency, are operated 200-Hz off-resonance through an ac current whose reference frequency is provided by the resonator embedded in an oscillating circuit. The sensors gain is increased by adopting a current recirculation strategy using metal strips directly deposited on the structural polysilicon. At a driving value of 100 μArms flowing in series through the three devices, the magnetometers show a sub-185 nT/Hz Hz resolution with a selectable bandwidth up to 50 Hz. Over a ±5-mT full-scale range, the sensitivity curves show linearity errors lower than 0.2%, with high cross-axis rejection and immunity to external accelerations. Under temperature changes, the stability of the 200-Hz difference between the magnetometers and the resonator frequency is within 55 ppm/K. Offset is trimmed down to the microtesla range, with an overall measured Allan stability of about 100 nT at 20-s observation time. [2016-0030]

A 3-D micromechanical multi-loop magnetometer driven off-resonance by an on-chip resonator

LAGHI, GIACOMO;MARRA, CRISTIANO ROCCO;MINOTTI, PAOLO;TOCCHIO, ALESSANDRO;LANGFELDER, GIACOMO
2016-01-01

Abstract

This paper presents the principle and complete characterization of a single-chip unit formed by microelectromechanical system magnetometers to sense the 3-D magnetic field vector and a Tang resonator. The three sensors, nominally with the same resonance frequency, are operated 200-Hz off-resonance through an ac current whose reference frequency is provided by the resonator embedded in an oscillating circuit. The sensors gain is increased by adopting a current recirculation strategy using metal strips directly deposited on the structural polysilicon. At a driving value of 100 μArms flowing in series through the three devices, the magnetometers show a sub-185 nT/Hz Hz resolution with a selectable bandwidth up to 50 Hz. Over a ±5-mT full-scale range, the sensitivity curves show linearity errors lower than 0.2%, with high cross-axis rejection and immunity to external accelerations. Under temperature changes, the stability of the 200-Hz difference between the magnetometers and the resonator frequency is within 55 ppm/K. Offset is trimmed down to the microtesla range, with an overall measured Allan stability of about 100 nT at 20-s observation time. [2016-0030]
2016
Acceleration rejection; Magnetometers; Microelectromechanical systems (MEMS) sensors; Navigation; Vibrations; Mechanical Engineering; Electrical and Electronic Engineering
File in questo prodotto:
File Dimensione Formato  
jmems_3ax_rev_final.pdf

accesso aperto

Descrizione: bozza pre print
: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 10.18 MB
Formato Adobe PDF
10.18 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1011535
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 19
social impact