This paper discusses instrumentation based on multiview parallel high temporal resolution (<50 ps) time-domain (TD) measurements for diffuse optical tomography (DOT) and a prospective view on the steps to undertake as regards such instrumentation to make TD-DOT a viable technology for small animal molecular imaging. TD measurements provide information-richest data, and we briefly review the interaction of light with biological tissues to provide an understanding of this. This data richness is yet to be exploited to its full potential to increase the spatial resolution of DOT imaging and to allow probing, via the fluorescence lifetime, tissue biochemical parameters, and processes that are otherwise not accessible in fluorescence DOT. TD data acquisition time is, however, the main factor that currently compromises the viability of TD-DOT. Current high temporal resolution TD-DOT scanners simply do not integrate sufficient detection channels. Based on our past experience in developing TD-DOT instrumentation, we review and discuss promising technologies to overcome this difficulty. These are single photon avalanche diode (SPAD) detectors and fully parallel highly integrated electronics for time-correlated single photon counting (TCSPC). We present experimental results obtained with such technologies demonstrating the feasibility of next-generation multiview TD-DOT therewith.

Prospects on Time-Domain Diffuse Optical Tomography Based on Time-Correlated Single Photon Counting for Small Animal Imaging

RECH, IVAN
2016-01-01

Abstract

This paper discusses instrumentation based on multiview parallel high temporal resolution (<50 ps) time-domain (TD) measurements for diffuse optical tomography (DOT) and a prospective view on the steps to undertake as regards such instrumentation to make TD-DOT a viable technology for small animal molecular imaging. TD measurements provide information-richest data, and we briefly review the interaction of light with biological tissues to provide an understanding of this. This data richness is yet to be exploited to its full potential to increase the spatial resolution of DOT imaging and to allow probing, via the fluorescence lifetime, tissue biochemical parameters, and processes that are otherwise not accessible in fluorescence DOT. TD data acquisition time is, however, the main factor that currently compromises the viability of TD-DOT. Current high temporal resolution TD-DOT scanners simply do not integrate sufficient detection channels. Based on our past experience in developing TD-DOT instrumentation, we review and discuss promising technologies to overcome this difficulty. These are single photon avalanche diode (SPAD) detectors and fully parallel highly integrated electronics for time-correlated single photon counting (TCSPC). We present experimental results obtained with such technologies demonstrating the feasibility of next-generation multiview TD-DOT therewith.
2016
sezele
File in questo prodotto:
File Dimensione Formato  
Journal of Spectroscopy 2016 Bérubé-Lauzière_reduced.pdf

accesso aperto

Descrizione: MainPaper
: Publisher’s version
Dimensione 7.07 MB
Formato Adobe PDF
7.07 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1009630
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 13
social impact