Rem-Counters are widely used in radiation protection practice for environmental neutron detection. They are usually based on both an active and a passive thermal neutron detector surrounded by a hydrogenate moderator designed to obtain a response function as close as possible to the H*(10) curve. Inclusion of high Z material is also used to extend the response function up to 1 GeV of neutron energy. Recently a dual detector Rem-Counter, both active and passive, was proposed by Agosteo et al. (2010). The present paper focuses on the passive version that is based on a CR-39 track detector coupled to an enriched 10 B converter. A technique was developed for the track analysis based on the measurement of the mean LETof the charged particles produced by the neutron reaction on 10B that has proven to be verye ffective in the background reduction. Moreover the simulated response function of the Rem-Counterwas compared with the experimental results obtained with irradiations carried out with mono-energetic neutron beams, showing a quite good agreement.

Calibration of a passive rem counter with monoenergetic neutrons

CARESANA, MARCO;FERRARINI, MICHELE;SASHALA NAIK, ALVIN
2014-01-01

Abstract

Rem-Counters are widely used in radiation protection practice for environmental neutron detection. They are usually based on both an active and a passive thermal neutron detector surrounded by a hydrogenate moderator designed to obtain a response function as close as possible to the H*(10) curve. Inclusion of high Z material is also used to extend the response function up to 1 GeV of neutron energy. Recently a dual detector Rem-Counter, both active and passive, was proposed by Agosteo et al. (2010). The present paper focuses on the passive version that is based on a CR-39 track detector coupled to an enriched 10 B converter. A technique was developed for the track analysis based on the measurement of the mean LETof the charged particles produced by the neutron reaction on 10B that has proven to be verye ffective in the background reduction. Moreover the simulated response function of the Rem-Counterwas compared with the experimental results obtained with irradiations carried out with mono-energetic neutron beams, showing a quite good agreement.
2014
SSNTD, Neutron, Rem counter, Track detectors
File in questo prodotto:
File Dimensione Formato  
2014 Calibration of a passive rem counter with monoenergetic neutrons.pdf

Accesso riservato

Descrizione: articolo principale
: Publisher’s version
Dimensione 641.04 kB
Formato Adobe PDF
641.04 kB Adobe PDF   Visualizza/Apri
Calibration of a passive rem counter with monoenergetic neutrons_11311-861555_Ceresana.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 564.28 kB
Formato Adobe PDF
564.28 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/861555
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact