The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling, is calculated for different kinds of office rooms with a large glazed external surface. An example of cooling load calculation developed with the proposed procedure is given.

Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

CAUSONE, FRANCESCO;
2010-01-01

Abstract

The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling, is calculated for different kinds of office rooms with a large glazed external surface. An example of cooling load calculation developed with the proposed procedure is given.
2010
Solar radiation; Solar heat gains; Cooling load; Radiant panels; Heat Balance; Radiant Time Series
File in questo prodotto:
File Dimensione Formato  
Science Direct_ENB2691.pdf

Accesso riservato

Descrizione: published version
: Publisher’s version
Dimensione 748.94 kB
Formato Adobe PDF
748.94 kB Adobe PDF   Visualizza/Apri
Accepted Manuscript_ENB2691.pdf

accesso aperto

Descrizione: accepted manuscript
: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 521.04 kB
Formato Adobe PDF
521.04 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/722168
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 50
social impact