Failure analysis was performed on different brass electro-valves body affected by unexpected phenomena of cracking. Through the application of optical and scanning electron microscopy, micro hardness Vickers test and X-ray diffraction, the causes of damage were identified. The study showed the dependence between roughness and residual stress associated to the tool wear. A solution to avoid the failure is finally proposed, based on the use combination of a tool with controlled wear and stress relieving heat treatment.

Influence of the residual stresses induced by tool wear on the failure of brass electro-valves

MAPELLI, CARLO;MOMBELLI, DAVIDE;BARELLA, SILVIA;GRUTTADAURIA, ANDREA
2013-01-01

Abstract

Failure analysis was performed on different brass electro-valves body affected by unexpected phenomena of cracking. Through the application of optical and scanning electron microscopy, micro hardness Vickers test and X-ray diffraction, the causes of damage were identified. The study showed the dependence between roughness and residual stress associated to the tool wear. A solution to avoid the failure is finally proposed, based on the use combination of a tool with controlled wear and stress relieving heat treatment.
2013
File in questo prodotto:
File Dimensione Formato  
Valvole CEME.pdf

Accesso riservato

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 2.33 MB
Formato Adobe PDF
2.33 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/683997
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 4
social impact