Simulated moving-bed (SMB) technology is attracting increased interest for application to the separation of pharmaceuticals and fine chemicals, particularly to enantioseparations. Unlike the large-scale UOP Sorbex process, these small-scale units rise a series of HPLC columns, and the volume of the connecting lines may become comparable to the volume of the columns. In this work the effect of extra-column dead volume on SMB performance is analyzed, with the aim of providing a conceptual framework to account for it. In particular guidelines to design SMB operating conditions with nonnegligible extra-column dead volumes to achieve the desired separation performance are provided. These ave quantitatively assessed through comparison with the results obtained using a detailed SMB model which accounts for extra-column dead volumes. The model allows the extent and the role of extra-column band broadening due to the presence of dead volumes to be evaluated. A set of experimental results on a laboratory SMB unit is discussed in light of the theoretical findings.

Simulated moving-bed units with extra-column dead volume

MORBIDELLI, MASSIMO
1999-01-01

Abstract

Simulated moving-bed (SMB) technology is attracting increased interest for application to the separation of pharmaceuticals and fine chemicals, particularly to enantioseparations. Unlike the large-scale UOP Sorbex process, these small-scale units rise a series of HPLC columns, and the volume of the connecting lines may become comparable to the volume of the columns. In this work the effect of extra-column dead volume on SMB performance is analyzed, with the aim of providing a conceptual framework to account for it. In particular guidelines to design SMB operating conditions with nonnegligible extra-column dead volumes to achieve the desired separation performance are provided. These ave quantitatively assessed through comparison with the results obtained using a detailed SMB model which accounts for extra-column dead volumes. The model allows the extent and the role of extra-column band broadening due to the presence of dead volumes to be evaluated. A set of experimental results on a laboratory SMB unit is discussed in light of the theoretical findings.
1999
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/659664
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact