In this work a multi-story residential building located in Cinisello Balsamo, near Milan, was considered as case study for the application of two new prefabricated building systems for the energy retrofit. The first one, developed within EASEE, a European project funded by 7th Framework Program, consists in a preassembled insulated panel for the retrofit of facades, based on two TRC thin precast layers rigidly connected to an EPS core. The panels can be easily applied on the external side of existing facades without the use of scaffoldings, providing an additional efficient insulation as well a new external cladding. The second one consists in a preassembled timber panel for existing pitched roofs. The process includes the substitution of the existing roof with modular integrated panels with a high content of recycled materials that can be easily fixed on the existing structures (timber frames, concrete, masonry, etc.). The combination of the two prefabricated construction systems, applied on the case study, allowed the reduction of the building energy demand by 82%.

Prefabrication as large-scale efficient strategy for the energy retrofit of the housing stock: an Italian case study

PITTAU, FRANCESCO;MALIGHETTI, LAURA ELISABETTA;IANNACCONE, GIULIANA;MASERA, GABRIELE
2017-01-01

Abstract

In this work a multi-story residential building located in Cinisello Balsamo, near Milan, was considered as case study for the application of two new prefabricated building systems for the energy retrofit. The first one, developed within EASEE, a European project funded by 7th Framework Program, consists in a preassembled insulated panel for the retrofit of facades, based on two TRC thin precast layers rigidly connected to an EPS core. The panels can be easily applied on the external side of existing facades without the use of scaffoldings, providing an additional efficient insulation as well a new external cladding. The second one consists in a preassembled timber panel for existing pitched roofs. The process includes the substitution of the existing roof with modular integrated panels with a high content of recycled materials that can be easily fixed on the existing structures (timber frames, concrete, masonry, etc.). The combination of the two prefabricated construction systems, applied on the case study, allowed the reduction of the building energy demand by 82%.
2017
Refurbishment; Energy retrofit; Prefabrication; Recladding; Roof
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1877705817317836-main.pdf

accesso aperto

Descrizione: Articolo principale
: Publisher’s version
Dimensione 469.49 kB
Formato Adobe PDF
469.49 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1024876
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 11
social impact