In the Middle Ages, Pavia was characterized by the presence of several masonry towers; some of them are still existing in the historic center, while many others failed or were demolished in the past centuries. Since 1989, when the collapse of the Civic Tower occurred, the municipality of Pavia started a huge program of analysis and verifications for all the survived towers, in order to evaluate their residual resistance and to prevent further collapses. Structural evidences required some consolidation interventions for three towers (San Dalmazio, Maino and Fraccaro). In this memory two similar interventions realized by the author on the tower of San Dalmazio and Maino are presented. The consolidation solution is called "tower in tower", and consists in the insertion of a steel truss tower inside the masonry one, connected to the perimeter walls through more than 300 steel stays. Such elements are able to transfer part of the self weight of the masonry to the inner steel truss, reducing the compressive stresses at the base.

La "Torre nella torre". Due casi di consolidamento a Pavia

JURINA, LORENZO
2016-01-01

Abstract

In the Middle Ages, Pavia was characterized by the presence of several masonry towers; some of them are still existing in the historic center, while many others failed or were demolished in the past centuries. Since 1989, when the collapse of the Civic Tower occurred, the municipality of Pavia started a huge program of analysis and verifications for all the survived towers, in order to evaluate their residual resistance and to prevent further collapses. Structural evidences required some consolidation interventions for three towers (San Dalmazio, Maino and Fraccaro). In this memory two similar interventions realized by the author on the tower of San Dalmazio and Maino are presented. The consolidation solution is called "tower in tower", and consists in the insertion of a steel truss tower inside the masonry one, connected to the perimeter walls through more than 300 steel stays. Such elements are able to transfer part of the self weight of the masonry to the inner steel truss, reducing the compressive stresses at the base.
2016
ReUSO2016. IV convegno internazionale sulla documentazione, conservazione e recupero del patrimonio architettonico e sulla tutela paesaggistica
978-88-7970-816-6
Masonry towers, structural consolidation, monitoring, numerical modeling
File in questo prodotto:
File Dimensione Formato  
Jurina_ articolo san dalmazio.pdf

Accesso riservato

Dimensione 1.44 MB
Formato Adobe PDF
1.44 MB Adobe PDF   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1015720
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact