A hybrid Closed Loop Thermosyphon/Pulsating Heat Pipe with an inner diameter bigger than the capillary threshold is tested both on ground and in hyper/microgravity conditions. The device, partially filled up with FC-72, consists of an aluminum tube (inner diameter: 3. mm) bent into a planar serpentine with five curves at the evaporator. A transparent section closes the loop in the condenser zone, allowing fluid flow visualization. Five heaters are mounted alternatively on the branches, just above the turns and controlled independently, in order to investigate the effect of non-uniform heating configurations. On ground, where the device works as a thermosyphon, the non-uniform heating configurations promote the fluid net circulation in a preferential direction, increasing the thermal performance with respect to the homogeneous heating. Parabolic flights point out that during the 20. s of microgravity, the sudden absence of the buoyancy force activates an oscillating slug/plug flow regime, typical of the Pulsating Heat Pipes, allowing the device to work also without the assistance of gravity. Furthermore, peculiar heating configurations can shorten the stop-over periods and stabilize the pulsating two-phase flow motion.

Hybrid Pulsating Heat Pipe for space applications with non-uniform heating patterns: Ground and microgravity experiments

ARANEO, LUCIO TIZIANO;
2017-01-01

Abstract

A hybrid Closed Loop Thermosyphon/Pulsating Heat Pipe with an inner diameter bigger than the capillary threshold is tested both on ground and in hyper/microgravity conditions. The device, partially filled up with FC-72, consists of an aluminum tube (inner diameter: 3. mm) bent into a planar serpentine with five curves at the evaporator. A transparent section closes the loop in the condenser zone, allowing fluid flow visualization. Five heaters are mounted alternatively on the branches, just above the turns and controlled independently, in order to investigate the effect of non-uniform heating configurations. On ground, where the device works as a thermosyphon, the non-uniform heating configurations promote the fluid net circulation in a preferential direction, increasing the thermal performance with respect to the homogeneous heating. Parabolic flights point out that during the 20. s of microgravity, the sudden absence of the buoyancy force activates an oscillating slug/plug flow regime, typical of the Pulsating Heat Pipes, allowing the device to work also without the assistance of gravity. Furthermore, peculiar heating configurations can shorten the stop-over periods and stabilize the pulsating two-phase flow motion.
2017
Microgravity; Non-uniform heating; Pulsating Heat Pipe; Thermosyphon; Energy Engineering and Power Technology; Industrial and Manufacturing Engineering
File in questo prodotto:
File Dimensione Formato  
ATE-2017_1-s2.0-S1359431117301941-main.pdf

Accesso riservato

Descrizione: paper
: Publisher’s version
Dimensione 5.64 MB
Formato Adobe PDF
5.64 MB Adobe PDF   Visualizza/Apri
11311-1013221_Araneo.pdf

accesso aperto

: Post-Print (DRAFT o Author’s Accepted Manuscript-AAM)
Dimensione 5.18 MB
Formato Adobe PDF
5.18 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11311/1013221
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 46
social impact